INSTALLATION
12
INSTALLING FACADES
Install facades on case lineup using supplied hardware. Note location(s) of controller box in facade cutout for the
various case lengths. Attach with brackets and screws.
Facade screwed into Front Channel.
Fasten Facade to top of
Case using Self-Drilling
screws (every 2 feet).
End Facade not
shown for clarity
Field Installation 2&3-Door Cases
P/N 3124450_A
Vertical Support Guide for different Case lengths
Vertical Support
Facade screwed into Supports.
5-Door Facade
4-Door Facade
Support screwed into top of Case
Vertical
Supports
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
Channel screwed
(Top View)
into Top Frame.
Facade screwed into Supports.
Facade screwed into Front Channel.
Support screwed into top of Case
Facade
Fasten Facade to top of
Case using Self-Drilling
Evaporation Pan to be located in
screws (every 2 feet).
this area for 4 & 5-door cases.
3-Door Facade
2-Door Facade
Channel screwed
into Top Frame.
Vertical Support
NOTE:
Service Disconnect
can be mounted on
wall or top of case
for easy service
Vertical
access.
Supports
Field Installation
4 & 5-Door Cases