2048 channel converter card

Advertisement

Quick Links

G-Converter 2048 Channel Card
TECHNICAL:
SALES:
FAX:
ADDRESS:
WEB:
(0118) 965 6000
(0118) 965 5100
(0118) 965 5001
464 Basingstoke Road, Reading, Berkshire RG2 0QN
www.blackbox.co.uk
G-Converter 2048 Channel Card:
MTU200CF-2048
Rev 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Black Box G-Converter 2048

  • Page 1 G-Converter 2048 Channel Card: MTU200CF-2048 Rev 1.0 G-Converter 2048 Channel Card TECHNICAL: (0118) 965 6000 SALES: (0118) 965 5100 FAX: (0118) 965 5001 ADDRESS: 464 Basingstoke Road, Reading, Berkshire RG2 0QN WEB: www.blackbox.co.uk...
  • Page 2 G-Converter 2048 Channel Card How To Contact your Local Black Box Italy: Australia: Black Box Italia S.P.A Black Box Catalog Australia PTY LTD Tel: 0227400280 Tel: 0398797100 Fax: 0227400219 Fax: 0398702955 Web Site: www.blackbox.it Deutschland: Brazil: Black Box Deutschland Black Box Do Brasil.
  • Page 3 G-Converter 2048 Channel Card France: U.S.A Black Box Catalogue Black Box Corporation Tel: 0145606700 Tel: 724-746-5500 Fax: 0145606747 Fax: 724-746-0746 Web Site: www.blackbox.fr Web Site: www.blackbox.com Spain: Chile Black Box Comunicaciones S.A. Black Box Chile Tel: 34 91 663 0200...
  • Page 4 TO SAFETY INSTRUCTIONS IN APPENDIX A, AND EMC INSTRUCTIONS IN APPENDIX C The following declaration is made assuming the G-Converter 2048 Channel Cards have been installed correctly in an G-Converter Chassis. Certified Compliant in the EC, when fitted in accordance with the installation instructions,...
  • Page 5: Table Of Contents

    Appendix F – RJ45 E1 Crossover Cable..............16 Appendix G – X.21/V.11 Data Channel Pinout............17 Appendix H – V.35 DCE Pinout................. 18 Appendix I - V.35 Stub Cable..................19 Appendix J – Position of Links on the G-Converter 2048 Channel Card....20 TECHNICAL: 0118 931 2233...
  • Page 6: Introduction

    The intended use of this unit is to terminate G.703 links G-Converter 2048 The G-Converter 2048 is a low cost simple converter. The card has no management and can only be configured using link settings. A G-Converter manager card will not recognise a G- Converter 2048 Channel Card.
  • Page 7: Typical Applications

    G-Converter 2048 Channel Card Typical applications Typically the G-Converters are used to connect a router with an X.21/V.11 or V.35 interface to an E1 circuit with G.703 interface TECHNICAL: 0118 931 2233...
  • Page 8: Installation

    G.703 Interface Presentation 120Ohm. A shielded RJ45 connector is provided on the rear of the G-Converter 2048 Channel Card. The port is compliant with TBR12. A pin out of this connector is given in Appendix D.
  • Page 9: Dce Interface

    G-Converter 2048 Channel Card V.35 DCE Interface This interface is presented on a 15-way D-type female connector. A pin out of this connector is given in Appendix G. TECHNICAL: 0118 931 2233...
  • Page 10: Configuration And Use - G-Converter 2048 Channel Card

    G-Converter 2048 Channel Card Configuration and Use – G-Converter 2048 Channel Card There are configuration links on the G-Converter 2048 Channel Card. Selection of the interface is made by choosing the appropriate rear card. X.21/V.11 Interface When an X.21 type rear card is plugged in then the DTE interface is presented as X.21. The connector pin out for the X.21 interface is given in the Appendix G.
  • Page 11: Interface

    Detector Control signals The G-Converter 2048 supports one input flag and two output flags. RTS would normally be the definition for Flag 1 I/P as this is the only I/P called up by the V.35 spec. The two output flags, Flag 2 O/P and Flag 3 O/P can be assigned to RFS, DSR or DCD, the choice is at the discretion of the user.
  • Page 12: Front Panel Led Indicator

    G-Converter 2048 Channel Card Front panel LED indicator The G-Converter 2048 Channel Card has one LED indicator LED C NOTES OLOUR TATUS Link faulty No RX Carrier established. GREEN Link good Normal operation No power LED faulty, Unit faulty SALES: 0118 965 5100...
  • Page 13: Appendix A - Warnings0

    G-Converter 2048 Channel Card Appendix A - Warnings0 WARNING: This equipment relies on the EARTH/GROUND connection to ensure EMC compliance. It must not under any circumstances be operated without an earth connection, which could nullify its approval. WARNING: INSTALLATION OF EQUIPMENT Installation of this equipment must only be performed by suitably trained service personnel.
  • Page 14: Appendix B - Approval Requirements

    G-Converter 2048 Channel Card Appendix B – Approval Requirements The G-Converter 2048 Channel Card Converter carrying the BABT/CE168 assessment symbols and approval number, is approved for connection to the networks identified in this Appendix as follows: G.703 Throughout Europe (Pan European) to CTR12 and CTR13 via RJ45 Connector (120 Ohms Balanced) The 75 Ohms unbalanced variant is approved to PD7024.
  • Page 15: Appendix C - Emc Requirements

    G-Converter 2048 Channel Card Appendix C – EMC Requirements To ensure compliance with the EMC directive, some care must be taken to ensure that the units are installed properly, using suitable cables and connections. The following must be observed: Limitation of Emissions: 'D-Type' Connections This product relies on the use of screened cables for connection to the 15 way 'D-Type' ports.
  • Page 16: Appendix D - G.703 120 Ohms Interface Pinout

    G-Converter 2048 Channel Card Appendix D - G.703 120 Ohms Interface Pinout COMPOSITE INTERFACE CONNECTIONS (EUROPE) USING 120 OHM BALANCED RJ45 Name Description Type at Connector DTE – RJ45 Female RX Pair Input RX Pair Input TX Pair Output TX Pair...
  • Page 17: Appendix G - X.21/V.11 Data Channel Pinout

    G-Converter 2048 Channel Card Appendix G – X.21/V.11 Data Channel Pinout X.21/V.11 Data Channel connectors (15 Way DB25 Type Configured DCE) DATA CHANNEL CONNECTIONS Name Description Type at Connector DCE – DB15 Female Protective Ground Signal Ground T(A) TxDa Input...
  • Page 18: Appendix H - V.35 Dce Pinout

    G-Converter 2048 Channel Card Appendix H – V.35 DCE Pinout 15 Way female D type configured as DCE DATA CHANNEL CONNECTIONS Number Name Type at Connector DCE – DB15 Female Protective Ground Signal Ground Bidirectional See note 1 Flag 3 I/P V.28 Input...
  • Page 19: Appendix I - V.35 Stub Cable

    G-Converter 2048 Channel Card Appendix I - V.35 Stub Cable V.35 Stub cable 15 way D type Name Type MRAC 34 pin connector Male Female Protective Ground Shield Signal Ground Bidirectional RTS(Flag 3 I/P) V.28 Input ExtClk(A) V.11 Input ExtClk(B) V.11 Input...
  • Page 20: Appendix J - Position Of Links On The G-Converter 2048 Channel Card

    G-Converter 2048 Channel Card Appendix J – Position of Links on the G-Converter 2048 Channel Card SALES: 0118 965 5100...