Connections; Type Designation Label - ABB FSO-12 User Manual

Safety functions module
Table of Contents

Advertisement

No Description
8
Input / output connections
• 4 redundant or 8 single digital inputs, or combinations of redundant and single inputs.
Possible redundant pairs: X113:1 & X114:1, X113:2 & X114:2, X113:3 & X114:3 and
X113:4 & X114:4.
• 3 redundant or 6 single digital outputs, or combinations of redundant and single
outputs. Possible redundant pairs: X113:7 & X114:7, X113:8 & X114:8 and X113:9 &
X114:9.
• two 24 V DC reference outputs with configurable diagnostic pulses.
9
Factory reset button (under the label)

Connections

The FSO module has several safety I/Os for external safety devices, for example
buttons, gates and indicators. The FSO-12 module does not have the ability to
interface to an encoder.
When you use the Safe brake control (SBC) function, the FSO module controls the
mechanical brake. For more information on the SBC function, see chapter
functions.
One FSO module is needed for each drive/inverter to be monitored.
Connection details are described in section

Type designation label

The type designation label is attached on the top of the FSO module. An example
label and description of the label contents are shown below.
1
4
No Description
1 Type
2 Serial number of format RYWWSSSS, where
R:
Component revision: A, B, C, ...
Y:
Last digit of the manufacturing year: 4, 5, ... for 2014, 2015, ...
WW:
Manufacturing week: 01, 02, ... for week 1, week 2, ...
SSSS:
Integer starting every week from 0001
3 ABB MRP code of the FSO module
4 Combined ABB MRP code, serial number and manufacturing location
5 RoHS mark
2
Terminals
on page 212.