298 Parameters
Index
Name/Value
DI X113:3 & X114:3 Redundant input X113:3 & X114:3
DI X113:4 & X114:4 Redundant input X113:4 & X114:4
DI X113:1
DI X113:2
DI X113:3
DI X113:4
DI X114:1
DI X114:2
DI X114:3
DI X114:4
POUS.13 POUS delay for
completion
0...3,600,000 ms
POUS.21 POUS output
None
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
DO X113:8
DO X113:9
DO X114:7
DO X114:8
DO X114:9
POUS.22 POUS completed
output
None
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
DO X113:8
Description
Single input X113:1
Single input X113:2
Single input X113:3
Single input X113:4
Single input X114:1
Single input X114:2
Single input X114:3
Single input X114:4
Sets the time after which the POUS
complete indication is activated after the
POUS request.
Time
Sets the digital output that indicates the
activity of the POUS function. Active from
the POUS request until the function has
been acknowledged.
No output connected
Single output X113:7
Single output X113:8
Single output X113:9
Single output X114:7
Single output X114:8
Single output X114:9
Set the digital output that indicates the
completion of the POUS function. Active
after the time defined by parameter
POUS.13 POUS delay for completion
elapsed from the POUS request until the
POUS request has been removed.
Note: Connect the POUS indication lamp to
this output.
No output connected
Single output X113:7
Single output X113:8
Factory
default
0 ms
None
None