AXIS M11-E Series
Specifications
Function
DC ground
DC output
Digital Input
Digital Output
Example
1
DC ground
2
DC output 12 V, max 25 mA
3
Digital input
4
Digital output
Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate.
4
Internally connected to pin 1 (DC ground) when active,
and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with
the load, to protect against voltage transients.
24
Specifications
0 V DC
12 V DC
Max load = 25 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA