SETTING UP SERIAL PORTS
Serial Port Configuration
On the
current serial port. Parameters include port mode, baud rate, data bits, parity, stop bits and type of flow
control.
Mode
1.
- select the type of serial connection (RS-232, RS-422, RS-485 2-wire or RS-485 4-wire)
required to connect the serial device to the serial server.
Baud Rate
2.
- select the Baud Rate (between 75 baud and 230,400 baud) required to
communicate with the serial device connected to the serial server.
Data Bits
3.
- select the number of Data Bits (5, 6, 7 or 8) required to communicate with the serial
device connected to the serial server.
Stop Bits
4.
- select the number of Stop Bits (1, 1.5, or 2) required to communicate with the serial
device connected to the serial server.
Parity
5.
- select the Parity setting (None, Even, Odd, Mark or Space) required to communicate
with the serial device connected to the serial server.
Flow Control
6.
communicate with the serial device connected to the serial server.
BB-VESP211x Serial Servers
page, you can configure the communications parameters of the
Figure 4.10 Serial Port Configuration Page
- select the Flow Control setting (None, RTS/CTS or XON/XOFF) required to
25
: