XW-111™ Wi-Fi Digital Sensor Users Manual
Enable XCD Encryption
If the XCD Method is selected, checking this box will enable the encryption of the XCD communications.
If the receiving device has the control page password enabled, you must use encryption and enter the
control page password in the Password field.
Password
This password is used to generate the encryption keys used for XCD when encryption is enabled. If
encryption is used, this password must be the control page password for the master device.
Periodic Reporting Interval
The XW-111 normally operates in a low power sleep mode. Whenever one of the inputs changes state it
awakens and tests the state of the digital inputs. The XW-111 also periodically awakens to check the
battery status as well as to update the remote master. Updating the remote master periodically indicates
the unit is still functioning correctly and submits the information the same as if an input has changed
state.
Xytronix Research & Design, Inc.
defines the location of a script or page that can accept the data being sent via POST or
GET. For example, if the script is located at www.example.com/xw111/logger.php, the
path would be xw111/logger.php
With POST or GET requests, the information is sent using key-value pairs. An example
of what this request would look like is listed below:
serial=XXXXXXXXXXXX&input1State=0&input2State=1&batteryLife=100
Web Server