Email on AC Power Fail
When enabled, the XW-111 will send a status email when it detects loss of the +5V input power source.
This feature only works if batteries are installed and power to the access point and internet is still
available. Another power-loss email will not be sent until power has been restored for a period of time.

EMAIL SETTINGS

SMTP Server
The SMTP mail server host name. To save energy, DNS lookups are only performed the first time after
the settings are submitted, or after a failure to send an email.
SMTP Server Port
The port number of the SMTP mail server. This is generally 25 for non-encrypted SMTP servers. If using
SSL/TLS, this port number is generally 465.
SSL
Check this check box if the server and port you have configured is expecting a SSL connection.
User Name
Email user name (if required).
Password
Email password (if required).
Return Email
The email address that will get a notification if the sent email does not send. (Note: Most email providers
require the Return Email address to match the address in the User Name field.)
Email 1-3
When an alert occurs an email message is sent to these addresses.
Test Email
Pressing this button will submit any changes to the email settings and trigger an alert email to be sent to
the configured email addresses.
The result of the test email will be displayed directly below the Test Email button along with the last
message received from the SMTP server, if applicable.
The following are typical responses you may see along with a description of what they mean:
Error initiating communications: Did not receive the expected HELO from SMTP server. Ensure
you are using the proper port and host/IP settings.
Error with EHLO: Error sending or error receiving proper response to the SMTP EHLO
command. Server may be unavailable or port and IP address settings are not correct.
Error authenticating: Error sending or error receiving proper response to the SMTP AUTH
PLAIN command. This may indicate the use of an incorrect username or password.
Error with FROM field: Error sending or error receiving proper response to the SMTP MAIL
FROM command. Ensure the Return Email address has been properly specified.
Error with RCPT(To) field: Error sending or error receiving proper response to the SMTP RCPT
TO command. Ensure the To email addresses are using valid characters and formatted
properly.