1ST PHASE (Adjustments and checks)
1 - Position all the SW1 and SW2 micro switches to OFF and dip 7 and 14 dip to ON (with electric lock also
put dip 8-9-10 to ON
2 - Supply power to the panel. Put DIP 1 to ON. The DL1 LED will flash.
3 - Move the leaves electrically to complete opening and closing position to adjust
the mechanical stops. To do this press PROG and keep it pressed. The DL5 and
DL3 LEDs at the side of the relays will turn on.
M1 and M2 must open as long as PROG is held down.
After 10 seconds the low speed starts to function.
Move the LOW SPEED trimmer to adjust it.
Turn the TORQUE trimmer clockwise to increase the power (if necessary).
5 - When it has fully opened adjust the correspondent mechanical stops.
6 - Release PROG. If necessary, reverse V with W of the motor(s) which close(s) to re-establish the correct
movement direction.
7 - Press PROG and keep it pressed down. The DL4 and DL6 at the side of the relay will turn on. M2 and then M1
must close. Keep PROG pressed down until closing is complete.
When it has closed completely adjust the correspondent mechanical stops.
8 - Put DIP1 to OFF. The DL1 LED will stop flashing.
2nd PHASE (Programming total opening time)
1 - Both leaves are closed. Put DIP 2 on ON. The DL1 LED flashes.
2 - Press PROG. The first leaf opens, recording the times (M2 remains still in the closed position)
3 - When M1 has finished opening, wait 2 seconds and press PROG (M1 times are stored)
4 - The second leaf starts opening, recording the times.
5 - When M2 has finished opening, wait 2 seconds and press PROG (M2 times are stored)
6 - Wait for the length of time wanted before automatic closing and press the PROG button.
7 - M2 closes. When the o set between the two leaves is such that they will not override each other when closing, press PROG to close
M1.
8 - M1 closes with no risk of overriding M2. DL1 stops flashing.
9 - Both motors have stopped. Times are stored
10 - Put DIP2 on OFF.
3rd PHASE Programming the remote control
1 - Put DIP 1 on ON and then DIP 2 of SW1 on ON => the DL1 LED flashes for 10 seconds.
ON
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
2 - Press the key on the remote (normally channel A) within 10 seconds. If the code is stored correctly
the green DL2 LED flashes once.
ON
3 - Code programming time is renewed automatically so the next remote control can be stored.
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
4 - To end programming wait 10 seconds or press the PROG button briefly => the DL1 LED stops flashing.
5 - Put DIP 1 and DIP 2 back on OFF.
4th PHASE (Programming pedestrian opening times)
1 - Both leaves are closed. Put DIP2 on ON. The DL1 LED flashes quickly.
2 - Put DIP1 on ON. The DL1 LED now flashes slowly.
3 - Make contact between the COM and Ped Butt terminals. The DL1 LED flashes.
4 - When the leaf is opened enough, again make contact between the COM and Ped Butt terminals. This
stops M1.
5 - Wait for the length of time wanted before automatic closing and then again make contact between the COM and Ped Butt terminals.
6 - M1 closes. The times are stored.
7 - Put DIP 1 and DIP2 of SW1 on OFF.
5th PHASE Customising the configuration
The configuration can be modified by moving the various microswitches
Microswitches ON
DIP 3
Automatic closing activated
DIP 4
Photocells active only in closing
DIP 5
Pre-flashing for 3 seconds
ON
DIP 6
K butt command and RADIO ine ective in opening
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
DIP 7
Slowing down activated
ON
DIP 8
Electric lock activated
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
DIP 9
Electric lock release stroke and easy release activated
DIP 10
Electric lock engage stroke activated
DIP 11
Black out function activated
(read the manual for more detail)
DIP 13
Sensitive edge monitoring SELFTEST activated
DIP 14 must remain to ON and DIPs 15 and 16 must remain to OFF for DUKE 230V.
ON
JP 17 Closed for 2 motors. Open for 1 motor.
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
JP1, JP2 and JP3 must be closed.
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
Microswitches OFF
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
Automatic closing deactivated
Photocells active all the time
Motor and flasher start together
K butt and RADIO step-by-step command
Slowing down not activated
Electric lock deactivated
Electric lock release stroke and easy release deactivated
Electric lock engage stroke deactivated
Black out function deactivated
Sensitive edge monitoring SELFTEST deactivated
ON
ON
ON
ON
ON
ON
ON