PREVENTIVE MAINTENANCE

dANgER OF ELECTRICAL ShOCK, TURN OFF ALL POwER SUPPLYINg ThIS EqUIPmENT
To ensure longer component life and trouble-free operation, minor preventive maintenance procedures
should be performed at regular intervals, for example once every year. More frequent inspection intervals
would be needed for more severe operating conditions and larger number of hours of continuous operation.
1. Remove front and side panels and at each service inspection any accumulated dust, dirt or foreign
particles should be carefully removed. Special care should be exercised in cleaning the thyristors
(SCR's), heat sinks and the control assembly.
2. Inverse Parallel Silicon Rectifiers (SCR's) or Thyristors - The silicon controlled rectifiers (SCR's or
Power Mods) usually fail in the shorted mode. When this happens, normally the fusible link in series
with the SCR will be blown open to clear the short and prevent damage to the transformers. If a blown
SCR is suspected, contact Transtector for service.
3. A simple performance checklist has been developed for use in maintenance. See "Performance
Checklist" and check off items 1-7.
4. After items 1-7 have been checked on the "Performance Checklist", the next step is to check the
operation of the system.
5. Replace front and side panels. Turn unit on with no load. Check item 8 on the "Performance Checklist"
6. Turn on loads and check items 9-10 off the "Performance Checklist".
7. Check to make sure all fans are operational and check off item 11.
NOTE: Preventive Maintenance Plans are available. Please contact the Customer Support Group for
information. Call 1-800-882-9110 X6112.
SERVICE
Transtector shall provide immediate phone support/consultation and if possible, same day parts shipment.
(contact must be prior to 12:00 PM PST). If necessary, on site service shall be scheduled the same day
for service to be conducted within 24 to 48 hours, based on customer requirements. Typical service hours
are 8 AM to 5 PM Monday through Friday.
Rick Ribbeck
Phone: (O) 208-635-6400 Ext. 5867 | (M) 208-762-6112
E-mail: rribbeck@infiniteelectronics.com