  • Page 1 Operating manual G 1107 Fine manometer...
  • Page 2: Table Of Contents

    Bases for measurement ........................ 16 Special functions.......................... 16 6.1.1 NVLL Tare function .......................... 16 6.1.2 F,NE High-resolution measurement with 0.1 Pa (G 1107).............. 16 6.1.3 AVR 0:02 / AVR 0:05 / AVR 0: 10 ...................... 17 Pressure connections .........................  17 UT operation ............................ 17 QC6 operation ............................
  • Page 3 Table of contents Battery .............................. 20 7.2.1 Battery indicator.......................... 20 7.2.2 Changing battery .......................... 20 Calibration and adjustment service.....................  21 7.3.1 Certificates............................ 21 Error and system messages...................... 22 Disposal.............................  23 Technical data...........................  24 Spare parts and accessories ...................... 25 Ordering code ...........................  26 Service ...............................
  • Page 4: About This Documentation

    1 | About this documentation G 1107 1 About this documentation 1.1 Foreword Read this document carefully and familiarise yourself with the operation of the product before you use it. Keep this document ready to hand and in the immediate vicinity of the product so that it is available to the personnel/user for reference at all times in case of doubt.
  • Page 5: Further Information

    G 1107 About this documentation | 1 Prerequisite All mandatory prerequisites are then listed for each step. Instruction Tasks to be carried out by the personnel / user are represented as numbered instruc- tions. Adhere to the sequence of the specified instructions.
  • Page 6: Safety

    2 | Safety G 1107 2 Safety 2.1 Explanation of safety symbols DANGER This symbol warns of imminent danger which can result in death, severe bodily injury, or severe property damage in case of non-observance. CAUTION This symbol warns of potential dangers or harmful situations which can cause damage to the device or to the environment in case of non-observance.
  • Page 7: Qualified Personnel

    G 1107 Safety | 2 The G 1107 is designed as a manometer and measures even the smallest pressure differential pressures of up to ±200 hPa with a maximum resolution of up to 0.1 Pa in air or in non-corrosive/non-ionising gases between the two pressure connections.
  • Page 8: Description

    3 | Description G 1107 3 Description 3.1 Scope of delivery Please check to ensure the completeness of the product after opening the package. You should find the following components: – Quick reference guide – Handheld measuring device, ready for operation, including batteries –...
  • Page 9: The Product At A Glance

    G 1107 The product at a glance | 4 4 The product at a glance 4.1 The G 1107 Top view Front view LCD Display Connection variants 4.2 Display elements Display Battery indicator Evaluation of the battery status Unit display...
  • Page 10: Connections

    4 | The product at a glance G 1107 Function key Press briefly Freeze measurement (Hold) Return to measurement display Call up next parameter Long press, 2s Start menu configuration, (ONF appears in the dis- play Close menu, changes are saved...
  • Page 11: Operation

    G 1107 Operation | 5 5 Operation 5.1 Commissioning 5.1.1 Explanation Description The product is switched on with the On/Off button. It may be necessary to configure the product after switching on. See Configuration [} p. 11]. Prerequisite – Sufficiently full batteries are inserted in the product.
  • Page 12: Configuring Parameters Of The Configuration Menu

    5 | Operation G 1107 Representation Call up menu Next parameter Change value Save changes Discard changes Press: Single step Product is Hold: Fast switched off change Outcome of an action The Configuration menu is closed after the last parameter.
  • Page 13: Open The Adjustment Menu

    G 1107 Operation | 5 Resolution RANG Selection display resolution AVTO Automatic switchover Adjusted to the lowest value, e.g. -20.00 .. +20.00 Adjusted to the highest value, e.g. -200.0 .. +200.0 Shut-off time POFF No automatic shut-off Automatic shut-off after a selected time in hours...
  • Page 14: Parameters Of The Adjustment Menu

    5 | Operation G 1107 Representation Call up menu Hold Release Release Outcome of an action The adjustment menu is closed after the last parameter. 5.2.5 Parameters of the adjustment menu Description Zero point – The zero point can be calibrated easily without additional tools. Both pressure con- nection ports can be connected to a hose for this purpose in order to eliminated in- terfering influences of air movement.
  • Page 15 G 1107 Operation | 5 NOTE If the product is switched off without saving the configuration, the last saved values are reproduced on the next start-up of the product. B-H88.0.21.DB2-1.0 15 / 28...
  • Page 16: Bases For Measurement

    The tare function is independent of the zero point correction accessible via the set- tings menu. 6.1.2 F,NE High-resolution measurement with 0.1 Pa (G 1107) High-resolution measurement for the finest adjustment work, 4 Pascal Test (test of chimney draft with living-space-independent single combustion) and many other finely- adjusted pressure applications.
  • Page 17: Avr 0:02 / Avr 0:05 / Avr 0: 10

    G 1107 Bases for measurement | 6 6.1.3 AVR 0:02 / AVR 0:05 / AVR 0: 10 Fast measurement with mean value over 2 s / 5 s / 10 s Mean value mode for measurement of heavily fluctuating pressures.
  • Page 18: St6 Operation

    6 | Bases for measurement G 1107 Fig. 6: QC6 Quick-Connect The practical quick-change connection is only suitable for plastic hoses with 6 mm outer diameter. The hose end must be clean and undamaged for connection. It is fit by simply pushing it in until the mechanical stop is reached. It is disconnected by simul- taneously pressing the ring on the upper end of the connection and pulling the hose.
  • Page 19: Protection Of Sensors With Use Of Filter Membranes

    G 1107 Bases for measurement | 6 NOTE Use a suitable tool for tightening and observe the maximum torque of 2 Nm! 6.8 Protection of sensors with use of filter membranes The product and the sensor can be protected easy and effectively with the use of filter membranes (e.g.
  • Page 20: Operation And Maintenance

    7 | Operation and maintenance G 1107 7 Operation and maintenance 7.1 Operating and maintenance notices NOTE Pressure connections must be protected from soiling. 7.2 Battery 7.2.1 Battery indicator If the empty frame in the battery display blinks, the batteries are depleted and must be replaced.
  • Page 21: Calibration And Adjustment Service

    G 1107 Operation and maintenance | 7 7.3 Calibration and adjustment service 7.3.1 Certificates The certificates are categorised as ISO calibration certificates and DAkkS calibration certificates. The purpose of the calibration is to verify the precision of the measuring device by comparing it with a traceable reference.
  • Page 22: Error And System Messages

    8 | Error and system messages G 1107 8 Error and system messages Display Meaning Possible causes Remedy No display, Battery depleted Battery depleted Replace battery unclear char- System error Error in the product Send in for repair acters or no...
  • Page 23: Disposal

    G 1107 Disposal | 9 9 Disposal Separation by material and recycling of device components and packaging must take place at the time of disposal. The valid regional statutory regulations and directives applicable at the time must be observed. NOTE The device must not be disposed of with household waste.
  • Page 24: Technical Data

    10 | Technical data G 1107 10 Technical data Measuring range Measuring range (Hi) Measuring range (Lo) -2000 .. +2000 Pa -200.0 .. +200.0 hPa (mbar) -20.00 .. +20.00 hPa (mbar) -2.900 .. +2.900 PSI -150.0 .. +150.0 mmHg (Torr) -20.00 ..
  • Page 25: Spare Parts And Accessories

    G 1107 Spare parts and accessories | 11 11 Spare parts and accessories A selection of spare parts and accessories for this product is listed below. Article Number Name Description 601060 GKK 1100 Case with nap foam, 340 x 275 x 83 mm...
  • Page 26: Ordering Code

    12 | Ordering code G 1107 12 Ordering code G1107 G11xx 1. Pressure connection 2x 1/8 inch port, incl. connections for 6x1 mm (4 mm inside) and 8x1 mm (6 mm inside) hoses. 2x 1/8 inch port, incl. quick-fit connector for hose outer Ø 6 mm 2x 1/8 inch port, incl.
  • Page 27: Service

    13 Service 13.1 Manufacturer If you have any questions, please do not hesitate to contact us: Contact GHM Messtechnik GmbH GHM GROUP - Greisinger Hans-Sachs-Str. 26 93128 Regenstauf | GERMANY Email: info@greisinger.de | www.greisinger.de WEEE reg. no. DE 93889386 13.2 Repairs processing Defective products are repaired professionally and quickly in our service centre.