2 Install the unit where the sunlight does not shine directly on the unit.
If the unit receives direct sunlight, build an awning to shade the cabinet.
scrape
3 There should be no obstacle, such as a fence or wall, within 50cm from the back of the cabinet because it will
prevent heat radiation of the condensor.
Restriction of outside air will greatly reduce the cooling and heating efficiency of the air conditioner.
4 Install the unit a little obliquely outward not to leak the condensed water into the room (about 10mm or 1/4
bubble with level).
5 Install the unit with its bottom portion 75~150cm above the floor level.
6 The power cord must be connected to an independent circuit. The yellow/green wire must be grounded.
7 Based on calculations in compliance with AS60335.2.40 there is no minimum safe floor area for the installation of
the air conditioners described in this manual.
8 After installation the power plug should be easily accessible.
45°
if the wall thickness is more than 220mm scrape the wall as shown above
Installation
The treatment of condensed water
1 Take out the drain pan and screws (provided within your air conditioner accessories bag)
2 Install the drain pan at the bottom of the unit and secure it with the screws provided.
3 Connect a suitable sized drain hose (not supplied) to the drain outlet located on the underside of the drain pan.
Step 2 Removing the front panel
1 Remove the screw from the frame. (see Fig.3)
2 Grasp the left corner in the frame's underside, then loosen the frame. (see Fig.4)
Step 3 Installation
1 Remove the screw, fix the chassis-fixing board and cabinet.
2 Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet. (see Fig.6)
3 When you need to drain off the water, install the drain plug on the frame. Then fix the cabinet onto the support,
(provided by the installer unless you elect to install yourself) (see Fig.7).
4 Push the unit chassis into the cabinet. (see Fig.8)
drain drain pan outlet
Installation Steps
plug
5 Fix the chassis and cabinet. (see Fig.5)
Step 4 Installing the frame
Step 1 Remove the front panel and the air filter
1 Hold the slot under the front panel, then uplift it outwards, and remove the front panel (See Fig.1).
2 Pinch the handle under the air filter and make the air filter arched, remove it from the slot from underside to upside
(See Fig.2).
1 Install the frame. (see Fig.9)
2 Fix the screws on the frame. (see Fig.3)
1 Install the air filter into the frame's slot from upside to underside. (see Fig.2)
2 Hang the front panel on the frame's buckle, then press the front panel into the frame's slot until hear a click. (see
Fig.10)
Fig. 8
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
screw rubber
wall
cabinet supporter
screws
Fig. 7
Fig. 9 Fig. 10