This guide is provided as a help and not a total solution for every installation.
Common sense and concern for customers equipment will make for a good installation.
FINAL INSTALL TEST – If the DataStorm folder has been copied over to your Desktop from the CD-ROM, simply open it and
run the DataStorm software.
Once the main screen is open, click on "Test Dish" to see the dish is working.
Test dish takes approx. 10 minutes to perform.
For the purposes of installation, we are only concerned that the dish is receiving commands from the computer.
Test Dish should be run again following the Calibration Tilt procedure.
DATASTORM SPECIFICATIONS
MOUNTING PLATE DIMENSIONS
48" inches long by 21 ¾" inches wide.
MOUNTING AREA REQUIRED
40" wide by 56" long
DISH STOWED DIMENSIONS
54" inches Long by 39 ½" inches wide
by 10 ½" inches tall.
DISH FACE DIMENSIONS
39 ½" wide.
TOTAL WEIGHT OF DISH MOUNT
105 lbs.
MAIN CONTROLLER BOX
1" inch tall, by 11" inches wide, by 9"
inches long. (Located inside the vehicle)
TRANSMIT AND RECEIVE MODEMS
12" long, by 7" wide by 3 ¾" tall (Stacked). (Located inside vehicle)
OPERATING PARAMETERS
-20 degrees F to 120 degrees F
POWER
12 Volt DC 2 amp for Main Controller
120 Volt AC for Modems