Download Print this page

Master Appliance HG-201D Service Instructions page 2

Advertisement

Element Kits – Part No's. 30082, 30083, 30084, 30085, 30086, 30087, 30088
WARNING:
Disconnect heat gun power cord and
allow the heat gun to cool before disassembly.
READ THE SERVICE INSTRUCTIONS CAREFULLY. FAILURE TO
EXACTLY FOLLOW THE INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY OR DAMAGE TO YOUR HEAT GUN. ALL
REPAIRS MUST BE PERFORMED BY A QUALIFIED REPAIR
TECHNICIAN.
If nozzle mounting screws are lost or damaged, replace only with
#6-40 steel machine screws, 3/16 inch minimum length to ¼ inch
maximum length.
THIS ELEMENT KIT CONSISTS OF:
ELEMENT, (1)
MICA INSULATOR, (1)
RUBBER WASHER, (1)
BRASS NUT, #2-56, (2)
SCREW, PAN HEAD, #4-40, (1)
TO REMOVE OLD ELEMENT
1. Remove (3) nozzle mounting screws.
2. Gently pull nozzle shield from gun housing.
3. Remove screws on housing,
Ⓒ,
and
(NOTE: Models
without the "A" or "B" suffix will
not have the
screw.)
Cover can now be lifted away.
4. Remove pan head screw and rubber washer holding
element to housing, being careful that rubber washer
does not fall back into the housing.
5. Carefully lift element from its position exposing (2)
element nuts holding wires to element. Remove nuts
from element and disconnect wires.
TO INSTALL NEW ELEMENT
1. Attach element lead wires with new brass nuts furnished in
replacement kit. Make sure they are tight for good electrical
connection.
2. Mount new element with pan head screw and rubber washer.
Rubber washer must be mounted between element and
mounting boss on housing. Be sure not to overtighten.
3. Gently press element lead wires down under blower
wheel to prevent rubbing during operation.
4. Discard the old mica insulator sheets and replace with
corrugated mica insulator supplied in kit. Wrap mica
insulator around coils of element, ensuring all coils are
covered and attach housing cover.
WARNING:
Failure to properly cover coils with
mica insulator could result in electrical short
5. Attach cover screws loosely.
6. Gently slide nozzle straight on, aligning ceramic element
with front nozzle indents and (3) rear nozzle screw
holes. Slide nozzle shield over nozzle, lining up
mounting holes. Install (3) mounting screws
loosely until started and then tighten. Tighten cover
screws.
Master Appliance Corp.
th
2420 18
St.
Racine, WI 53403-2381
USA
Shield,
not included in kit
Ⓑ & Ⓒ
Email: sales@masterappliance.com
Models HG-201, HG-201A, HG-202, HG-202A, HG-301, HG-301A, HG-302,
HG-302A, HG-501, HG-501A, HG-502, HG-502A, HG-501A-C, HG-501A-D,
HG-751, HG-751A/15, HG-751A-20, HG-751A, HG-751B, HG-752, HG-752A,
HG-751A-C, VT-750A, VT-752A, VT-750A-C, VT-752A-C, VT-750B, VT-750C,
VT-752C, VTS-750, VTS-752
TOOLS REQUIRED
SLOTTED (FLAT) SCREWDRIVER
#1 PHILLIPS SCREWDRIVER
3/16" HEX WRENCH
Element
Mica
Insulator
Nozzle,
not included in kit
Indents support
ceramic element
Wings of ceramic
element to be supported
by indents in nozzle
Brass Nuts,
(2), included in kit
Tel: 262-633-7791
PAGE 2 OF 2
Round Head Screw,
remove to open cover
Nozzle Mounting Screw,
(3), not included in kit
Pan Head Screw,
Included in kit
Element
Rubber Washer,
Included in kit
Mounting Boss
Element Lead Wires,
Attach to new element
with brass nuts
Element Contacts,
Must not touch each other and must not
touch housing. Maintain a minimum gap
of 1/8 inch.
www.masterappliance.com
P/N 58266 REV A
Do not touch
nozzle until cool
Flat Head Screw,
remove to open cover
Cover
in Housing

Advertisement