1.

Instructions for use

1.1

Safety instructions

Carefully study all the safety instructions for the
product to be retrofitted. The safety instructions must
be heeded.
All the safety instructions can be found in the following
product descriptions:
R
"BEA150/250/350" (1 689 979 798)
R
"BEA 050" (1 689 979 832)
R
"BEA 810/840/850" (1 689 979 962)
R
"ESA 3.110/3.240/3.250" (1 689 979 648)
R
"FSA 740" (1 689 979 895)
R
"FSA 750" (1 689 979 926)
1.2

Important information

Information on mandatory calibration can be found in
the enclosed "Calibration bulletin" (1 689 979 566).
!
Retrofitting is only to be performed by a service
center authorized by Bosch and with appropriate
service seal. Affix your service seal to the retrofitted
product and immediately inform the relevant calibra-
tion authorities of the retrofitting work.
The BEA 150 and the BEA 350 are subject to the
calibration regulations as per: Annex 18, Section 9
(EO 18-9) and Annex 18, Section 10 (EO 18-10).
1.3

Abbreviations

AMM
Exhaust gas measurement module
BEA
Bosch Emissions Analysis
EDIS
Electron. documentation and information system
KD
Service
NRS
Supplementary equipment set
ppm
parts per million
PTB
German Federal Physical Technical Institute
Robert Bosch GmbH
Instructions for use | 1 687 001 866 / 1 682 666 309 | 13
1 687 001 866 / 1 682 666 309 | 13
1.4

Scope of delivery

1.4.1

NRS 1 687 001 866

The NRS 1 687 001 866 is intended for retrofitting on
the BEA 150 for gasoline exhaust analysis. The scope of
delivery is as follows:
Designation
AMM
Exhaust gas probe
Exhaust gas sampling hose, 8 m, Viton
Coarse filter
Sticker, PTB
Sticker "Upgraded to BEA 350"
1.4.2

AMM 1 682 666 309

The exchange AMM is intended for retrofitting the
Andros measurement chamber on products already
featuring gasoline exhaust analysis with a Siemens
measurement chamber. Scope of delivery:
Designation
AMM
Sticker
1.5

Test equipment

R
Service PC (Laptop/PC)
R
Connecting cable 1 684 465 371
(between BEA PC and Service PC)
R
Service software "Bea_kd.exe"
R
General tools for mechanics/electricians
i
The service software "Bea_kd.exe" can be found in
EDIS in the 'EDIS\SOFTWARE\KDSOFT\BEA' direc-
tory. Do not start "Bea_kd.exe" from the CD/DVD but
rather from the drive of your service PC. If not yet
done, install EDIS on your service PC.
1.6

Sample gas

Use one of the following sample gases for re-adjust-
ment:
Sample
Content
gas
5 % CO
No. 4
7.5 % CO2
2000 ppm C3H8 (propane)
3.5 % by vol. CO
A
14 % by vol. CO2
2000 ppm by vol. C3H8 (propane)
| 13
en
Order number
1 687 023 419
1 680 790 049
1 680 706 043
1 687 432 005
1 681 102 490
1 687 432 005
Order number
1 687 023 419
1 681 102 573
Accuracy
± 1%
± 1%
|
1 689 978 505