CA-800-Install.book Seite 32 Mittwoch, 4. Juli 2007 3:05 15
Installation

6.2.7 Attach the cover frame

Tighten the screws carefully so that the cover frame is not damaged.
➤ Attach the cover frame (see fig. 5 on page 4, Pos. 5) with the four cy-
lindrical screws + washers M7 (see fig. 5 on page 4, Pos. 6) to the
system.
6.3

Configuration of system software

Before you first start up the system, adapt the controls according to the in-
stallation conditions. This must be done by the person installing the sys-
tem.
In configuration mode, the following system software parameters must be
set on the control panel (see fig. 10 on page 6):
Menu
level
1
2
3
4
The configuration mode can also be called if the undervoltage protection
has switched off the system and there is only residual voltage.
32
Parameter
Meaning
Set temperature The system starts with the temper-
ature defined here.
Low-voltage
The battery monitor switches the
cut-off
system off at the defined voltage.
Operating mode The system starts with the operat-
ing mode defined here.
Default
The parameters 1-3 can be
settings
returned to the default settings.
CoolAir
Default
setting
20 °C
ID number
4 = 23.5
Volt
0 =
Automatic
mode
--