Replacing the Input Filter Assembly
When you perform the next step, orientate the line filter assembly so that the side of the filter
assembly with the green/yellow wire is nearest the power entry module ground stud.
10. Position the line filter assembly at its mounting location on the power entry module. Install
the screws that secure the input filter assembly to the power entry module.
11. Place the ground cable assembly and the ground wires attached to the line filter assembly
and power cord on the power entry module ground stud. Install the nut that secures the
wires on the ground stud.
12. Connect the line filter cable to the lower PCA.
13. Connect the brown wire removed in Step 8 to the load terminal of the circuit breaker.
14. Connect the in-line connectors on the ends of the loose blue wires on the line filter assembly
and the power cord.
15. Position the circuit breaker at its mounting location on the power entry module. Install the
screws that secure the circuit breaker to the power entry module.
16. Position the power entry module near enough to the climber to connect the lower ribbon
cable to the lower PCA.
17. Connect the remote sensor cable and the magnet harness to the lower PCA.
Note:
Take care not to pinch the cables when you perform the next step.
18. Push the power entry module into the climber. Install the screws that secure the power entry
module to the climber frame.
19. Check the climber operation as described in Section Four, Checking Unit Operation.