Name
Address
Description
Motor Overload (OL1)
L1-01
0480h
Motor Selection
Motor Overload (OL1)
L1-02
0481h
Time Constant
Motor Overheat (OH3)
L1-03
0482h
Alarm Selection
Motor Overheat (OH4)
L1-04
0483h
Fault Selection
Motor Overheat Filter
L1-05
0484h
Power Loss Ride Thru
L2-01
0485h
Selection
Power Loss Ride Thru
L2-02
0486h
Minimum Baseblock
L2-03
0487h
Voltage Recovery Ramp
L2-04
0488h
Undervoltage Detection
L2-05
0489h
L2-06
048Ah
KEB Decel Time
Powerloss Ride Thru
L2-07
048Bh
Accel Time
L2-08
048Ch
KEB Frequency Gain
Stall Prevention During
L3-01
048Fh
Accel Selection
Stall Prevention During
L3-02
0490h
Accel Current Level
Stall Prevention During
L3-03
0491h
Accel Constant HP Area
Current Lower Limit
Stall Prevention During
L3-04
0492h
Decel Selection
Stall Prevention During
L3-05
0493h
Run Selection
Stall Prevention During
L3-06
0494h
Run Current Level
Overvoltage Inhibit
L3-11
04C7h
Selection
Overvoltage Inhibit
L3-12
04C8h
Voltage Level
L4-01
0499h
Speed Agree Level
L4-02
049Ah
Speed Agree Width
L4-03
049Bh
Speed Agree Level +/-
L4-04
049Ch
Speed Agree Width +/-
Frequency Reference
L4-05
049Dh
Loss Selection
Frequency Reference
L4-06
04C2h
Loss Gain
Table 4.11 "L" Parameters
Data
0
1
Standard Fan Cooled
2
Standard Blower Cooled
3
Vector Duty
0.1 ~ 5.0 min
0
Ramp to Stop
1
Coast to Stop
2
Fast-Stop (C1-09)
3
Alarm Only
0
Ramp to Stop
1
Coast to Stop
2
Fast-Stop (C1-09)
0.00 ~ 10.00 Sec
Time
0
1
Enabled - L2-02 Time
2
Enabled - CPU Active
0.0 ~ 25.5 Sec
Time
0.1 ~ 5.0 Sec
Time
0.0 ~ 5.0 Sec
Time
kVA Dep.
Level
0.0 ~ 200.0 Sec
0.0 ~ 25.5 Sec
0 ~ 300 %
0
1
General Purpose
2
0 ~ 200 %
0 ~ 100 %
0
1
General Purpose
2
3
Enabled - Braking Resistor
0
1
Decel Time 1 (C1-02)
2
Decel Time 2 (C1-04)
30 ~ 200 %
0
1
kVA Dep.
0.0 ~ 400.0 Hz
0.0 ~ 20.0 Hz
-400.0 ~ 400.0 Hz
0.0 ~ 20.0 Hz
0
Run at L4-06 x Previous
1
0.0 ~ 100.0 %
Range
Unit
Disabled
1
0.1 min
1
1
0.01 Sec
Disabled
1
0.1 Sec
0.1 Sec
0.1 Sec
1 VDC
0.1 Sec
0.1 Sec
1 %
Disabled
1
Intelligent
1 %
1 %
Disabled
1
Intelligent
Disabled
1
1 %
Disabled
1
Enabled
1 V
0.1 Hz
0.1 Hz
0.1 Hz
0.1 Hz
Stop
1
Reference
0.1 %
68
Access Level
Default
During
V/f
V/f
Run
w/PG
1
Q
Q
1.0 min
A
A
3
A
A
1
A
A
0.20 Sec
A
A
0
A
A
0.1 Sec
A
A
0.5 Sec
A
A
0.3 Sec
A
A
kVA Dep.
A
A
0.0 Sec
A
A
0.0 Sec
A
A
100 %
A
A
1
A
A
150 %
A
A
50 %
A
A
1
Q
Q
1
A
A
160 %
A
A
0
kVA Dep.
0.0 Hz
A
A
2.0 Hz
A
A
0.0 Hz
A
A
2.0 Hz
A
A
0
A
A
80.0 %
A
A
OLV
FV
OLV2
Q
Q
Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Q
Q
Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A