YASKAWA G7 Modbus Communication Manual page 54

Hide thumbs Also See for G7:
Table of Contents

Advertisement

Name
Address
Description
b1-01
0180h
Reference Source
b1-02
0181h
Run Source
b1-03
0182h
Stopping Method
b1-04
0183h
Reverse Operation
b1-05
0184h
Zero-Speed Operation
b1-06
0185h
Digital Input Scan Time
b1-07
0186h
Local / Remote Run Selection
Run Command at
b1-08
0187h
Programming Mode
Zero Speed Operation
b1-10
01DEh
Selection
b2-01
0189h
DC Injection Start Frequency
b2-02
018Ah
DC Injection Current
b2-03
018Bh
DC Injection Time at Start
b2-04
018Ch
DC Injection Time at Stop
Magnetic Flux Compensation
b2-08
0190h
Level at Start
Automatic Speed Search at
b3-01
0191h
Speed Search Current
b3-02
0192h
(Current Detection Method)
Speed Search Decel Time
b3-03
0193h
(Current Detection Method)
Search Delay
b3-05
0195h
(Either Method)
Search Detect Compensation
b3-10
019Ah
(Speed Detection Method)
Observer Proportional Gain
b3-13
019Dh
N4-08 During Speed Search
Bi-directional Search
b3-14
019Eh
Selection
(Speed Detection Method)
Search Restart Current Level
b3-17
01F0h
(Speed Detection Method)
Search Restart Detection Time
b3-18
01F1h
(Speed Detection Method)
Table 4.5 "B" Parameters
Data
0
1
2
Modbus Communication
3
4
0
1
2
Modbus Communication
3
0
1
2
DC Injection to Stop
3
Coast with Timer
0
Reverse Enabled
1
Reverse Disabled
0
Run at Frequency Ref
1
Run at Minimum
2
3
Run at Zero RPM
0
1 Scan (2.5 ms)
1
2 Scans (5.0 ms)
0
Cycle External Run
1
Accept External Run
0
1
0
1
0.0 ~ 10.0 Hz
0 ~ 100 %
0.0 ~ 10.0 Sec
0.0 ~ 10.0 Sec
0 ~ 1000 %
Speed Search Frequency
0
Method - Disable
Speed Search Frequency
1
Method - Enable
Start
Speed Search Current
2
Method - Disable
Speed Search Current
3
Method - Enable
0 ~ 200 %
0.1 ~ 10.0 Sec
0.0 ~ 20.0 Sec
1.0 ~ 1.2
0.1 ~ 2.0
0
1
0 ~ 200 %
0.0 ~ 1.0 Sec
Range
Unit
Operator
Terminals
1
Option Card
Pulse Input
Operator
Terminals
1
Option Card
Ramp to Stop
Coast to Stop
1
1
Stop
1
Frequency
1
1
Disabled
1
Enabled
Disabled
1
Enabled
0.1 Hz
1 %
0.01 Sec
0.01 Sec
1 %
1
1 %
0.1 Sec
0.1 Sec
0.01
0.1
Disabled
1
Enabled
1 %
0.01 Sec
54
Access Level
Default
During
V/f
V/f
Run
w/PG
1
Q
Q
1
Q
Q
0
Q
Q
0
A
A
0
1
A
A
0
A
A
0
A
A
1
0.5 Hz
A
A
50 %
A
A
0.0 Sec
A
A
0.5 Sec
A
A
0 %
2
A
A
Cntrl Meth
A
2.0 Sec
A
kVA Dep.
A
A
1.1
A
1
1
A
A
150 %
A
0.1 Sec
A
OLV
OLV
FV
2
Q
Q
Q
Q
Q
Q
Q
Q
Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A