Figure 7-9 Feature parameters
Table 7-3 Feature parameters
Parameter
MPPT multi-peak scanning
MPPT multi-peak scan interval
(min)
Issue 06 (2020-02-18)
Description
When the inverter is used in scenarios where PV strings are greatly shaded,
set this parameter to Enable, and then the inverter will perform MPPT
scanning at regular intervals to locate the maximum power.
Specifies the MPPT scanning interval.
This parameter is displayed when MPPT multi-peak scanning is set to
Enable.