It is also helpful if you bring our attention to any errors. Product program of Deutschmann Automation A detailed and topical outline of our product range can be found on our homepage at http://www.deutschmann.de 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
For it the device is addressed in the Profibus in accordance with the Deutschmann communication profile (see instruction manual „Communication Profile“). Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
The cam control transfers the process data back in every Profibus cycle. The length of the pro- cess data is dependent on the cam control and the selected module of the GSD-file (see chapter "Explanation:" on page 15). 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
As a confirmation the PLC waits for the first word of the request (0x8006 hex). Besides the PLC always gets the process data back (see chapter 4.3 "Process data in Multiturn- format" on page 10). Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
Command Address pointer Data Data Data not used not used 6 byte data from address pointer 16 bit logic write-request sync (starting phase) 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
The status information on the outputs start from byte 16 on. Here that amount of outputs is trans- fered that is supported by the cam control. Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
Page 11
WORD CAM_MT_TYPE 0x0007 Cams for Multiturn devices WORD DIRECTIONCAM_TYPE_NEW 0x000F Direction cams WORD AT_CAM_ST_TYPE 0x000B Angle-time cams WORD LOGIC_TYPE 0x000C Logic function WORD 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
Address of the first angle-cam-entry WORD 6.10 Angle-time cams: AT_CAM_ST Structure Value Function Length ProgNo BYTE Output BYTE WORD Duration 0x0001 - 0x7EF4 WORD 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
Offset_Length is the amount of bytes of the offset parameters, always starting at zero and ending at the address 10 in this example. Explanation: Type Length BOOL 1 bit BYTE 8 bits WORD 2 bytes DWORD 4 bytes 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
In order to generate the data component, click on “File" -> "Generate data component" (see pic- ture below); define the file name and save. Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
Adding or deleting IO8-expansions (optional) With a double click on Hardware you get to the overview. LOCON 200 + 2 IO8-expansions are default. 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
Profibus-DP -> Further fielddevices -> PLC Mark the existing Slave. An “L200-IO8“-expansion can now be added by using Drag + Drop. Afterwards the IO-address can be defined. Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
Importing and translating data components (optional) Under sources -> right mouse button -> external sources a data component, generated by the DBGenerator can be imported. 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
The data component (here DB1) defined in chapter 8.4.2 can be called by a double-click left. Under View change to Data view. Attention: The entry of all values is made in hexadecimal form! Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
Defining or deleting symbols (optional) If an IO8-expansion was added or deleted (chapter 8.4.1), then the symbolism is changed to Symbols. The following view comes up: 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
After confirming the line is deleted. Process data In order to have the process data displayed they have to be opened. Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
„Symbol". After pressing ENTER the line is brought up to date. 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
Profibus-Master. Besides, all electrical connection between LOCON and Master have to be esta- blished. After the rotation of a connected encoder the item modification should have become visible after the online function was called . Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
ROTARNOCK“). In a simple terminal window, such as WINLOC32 the ID can be changed with the key combination „Clrg + N“ or „Strg + N“. 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...
At ROTARNOCK 100 it is also possible to select the Profibus-ID externally. For further informa- tion please have a look at the manual „ROTARNOCK 100“. Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
= cable length in meters. This cable is required for the configuration of the fieldbus parameters (ID, DB-number etc.) via the RS232-interface. Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0 22.1.08...
“regular“ error) indicates an error, which can be analysed by means of the above stated table. The number can either be seen via the diagnosis data from Profibus or via the RS232-interface of the WINLOC32-online-window. 22.1.08 Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0...