Receivers
Figure 6-7 shows the input signal electrical circuit.
The input specifications are as follows:
Input voltage:
Downlevel: +0.6 volt at
42 mA, maximum
Up level:
+2.4 volts, minimum
Input current:
< 42 mA at +0.6 volt
Input impedance:
100 ohms
Logical 1:
< +1.0 volt
Logical 0:
> +2.5 volts
DPC adapter
input
Recommended
termination
customerdriver
+5 V +10%
150 ohms +10%
Twisted-pair
TTL open
300 ohms +2.5%
cable
collector driver
Ground
Impedance: 100 ohms
Maximum distance: 6.1 m (20 ft)
Ground
Downlevel
+0.6 V at 42 mA,
maximum
Figure 6-7.
Input signal electrical circuit