ABB Orion3 Base Excerpts From The Original Instructions page 9

Safety light grids
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Active unit
All the possible cases of visualization are explained in the table below except those relative to the Alignment mode
(see above).
Display
2TLC172295M0201 Rev A
2015-03-20
Status
Interlock
Interlock
OSSD ON
OSSD OFF
Normal operation mode,
OSSD OFF, interlock
Normal operation mode,
OSSD OFF, interlock
Error mode
Error mode
(critical)
Error mode
Error mode
AOPD OFF
Description
Detection zone free.
OSSD outputs off.
Beam(s) interrupted.
OSSD outputs off.
OSSD outputs on.
OSSD outputs off.
EDM function activated.
EDM function
deactivated.
OSSD error, one or
both.
OSSD outputs off.
Microprocessor error.
OSSD outputs off.
Optical error.
OSSD outputs off.
EDM error.
OSSD outputs off.
Power supply error.
OSSD outputs off.
9
Action
Push the RESET button to return to
normal operation.
Remove the object from the detection
zone and push the RESET button.
Check the wiring and connections of
the OSSD outputs. Make sure that
there is no short-circuit between them
or with the supply voltage.
Then Acknowledge.
If the error persists, contact your
ABB Jokab Safety representative.
Turn AOPD off and on. If the error
persists, contact your
ABB Jokab Safety representative.
Acknowledge the error. If the error
persists, contact your
ABB Jokab Safety representative.
Check the wiring and the connections
of EDM SELECTION and EDM as well
as the time sequence (see the
instruction manual, Time chart).
Acknowledge the error.
If the error persists, contact your
ABB Jokab Safety representative.
Check the wiring and connections of
the power supply. Check that its value
is within the allowed range.
If the error persists, contact your
ABB Jokab Safety representative.