ABB Orion3 Base Excerpts From The Original Instructions page 7

Safety light grids
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Display
1 ) Keep the active unit in a steady position and adjust the passive unit until the yellow LED (
This condition shows the alignment of the first transmitter/receiver couple.
2 ) Rotate the passive unit, pivoting around the lower optics axis, until the yellow LED (
NB: Make sure that the green LED (
3 ) Slightly turn both units both ways to find the limits of the area in which the green LED (
displayed (Maximum alignment). Place both units in the centre of this area.
4 ) Fix the two units firmly using brackets.
Check that the green LED (
the red LED (
) turns on when one single beam is interrupted. This check shall be made with the special
cylindrical "Test Piece" having a suitable size for the resolution of the device used (see paragraph "Checks after
first installation" of the instruction manual).
5 ) Switch the device off and on to normal operating mode.
The alignment level is also monitored during normal operating mode and visualized on the display.
Once the AOPD has been aligned and correctly fastened, the signal on the display is useful both to check the
alignment and to show a change in the environmental conditions (presence of dust, light disturbance and so on). The
behaviour is summarized in the next table.
Display
2TLC172295M0201 Rev A
2015-03-20
Alignment status
First and last couple are not aligned
Last couple is not aligned
First couple is not aligned
Every couple over the lower light reception
threshold and no couple over the upper light
reception threshold
Every couple over the lower light reception
threshold and one couple over the upper
light reception threshold
Every couple over the upper light reception
threshold
) is on and steady.
) on the active unit is on when the beams are not interrupted Then check that
Alignment status
Every couple over the lower light reception threshold
and no couple over the upper light reception threshold
Every couple over the lower light reception threshold
and one couple over the upper light reception
threshold
Every couple over the upper light reception threshold
Alignment
quality
Bad
Bad
Bad
Good
Excellent
7
Output status when
out of alignment
mode
OSSD OFF
OSSD OFF
OSSD OFF
OSSD ON
OSSD ON
OSSD ON
FIRST) turns off.
LAST) turns off.
) is steady and "3" is
Alignment quality
Min.
Excellent
www.abb.com/jokabsafety