6. Press and hold DTS button to clear error code to
zero.
ti13608a
7. Short press to move to SOFTWARE REV.
ti13613a
8. Short press to display number of GUN TRIGGERS
logged.
ti15694a
9. Short press to enter BLOCK mode. Hold DTS but-
ton in to block any active outside RF signals in the
area other than the current learned controller. The
screen will display the number of unwanted signals
being blocked. Up to 5 unwanted RF signals can be
blocked.
NOTE: To see the number of blocked signals, press and
hold the DTS button.
3A0245A
ti13614a
ti13623a
ti7362a
ti15691a
10. Short press to enter CLEAR mode. Hold in DTS
button to clear all RF signals that were being
blocked.
11. Short press to RF ON/OFF mode (this is used for
Troubleshooting only). To turn RF off and enter pres-
sure control mode, make sure flow control knob is at
zero. Hold DTS button until screen displays RFOFF.
Turn power switch OFF, then turn back ON. The dis-
play will show an asterisk to indicate that it is in
pressure control mode.
To return to flow control mode, turn power switch
OFF for approximately 45 seconds.
ti15695a