Graco 257100 Operation page 20

Drywall feed pump
Hide thumbs Also See for 257100:
Table of Contents

Advertisement

Troubleshooting
TYPE OF PROBLEM
Drywall feed pump does not
run at all
Digital display shows E=03
Control board status light
blinks 3 times repeatedly
20
WHAT TO CHECK
Check transducer or transducer
connections (control board is not
detecting a pressure signal).
HOW TO CHECK
1.
Turn unit OFF and disconnect power.
2.
Check transducer and connections to control board.
3.
Disconnect transducer from control board socket.
Check to see if transducer and control board
contacts are clean and secure.
4.
Reconnect transducer to control board socket.
Connect power, turn unit ON, set pump to PRIME
position, and turn control knob 1/2 turn clockwise. If
drywall feed pump does not run, turn unit OFF and
go to next step.
5.
Connect a confirmed working transducer to control
board socket.
6.
Connect power, turn unit ON, set pump to PRIME
position, and turn control knob 1/2 turn clockwise. If
drywall feed pump runs, install new transducer.
Replace control board if unit does not run.
7.
Check transducer resistance with ohmmeter (less
than 9k ohm between red and black wires and 3-6k
ohm between green and yellow wires).
3A0245A