Graco 257100 Operation page 8

Drywall feed pump
Hide thumbs Also See for 257100:
Table of Contents

Advertisement

Setup
Psi
ti13620a
NOTE: JOB scrolls past, then the number of gallons dis-
pensed displays.
2. Press and hold to reset to zero.
Lifetime Gallons
1. Short press DTS button to move to LIFE gallons (or
liters x 10). LIFE scrolls briefly, then the number of
gallons dispensed displays.
ti13601a
Learn the Controller
This unit uses two different controllers: an inline valve con-
troller for taping and corner finishing, and a box slide con-
troller for box finishing. Each time you change controllers,
perform the following steps so the unit can learn the con-
troller.
1. Turn flow control knob fully counterclockwise to OFF
position.
2. Push digital display button 3 times until LEARN
appears on display screen.
3. Pull trigger on controller.
ti15626a
4. OK will then appear on display screen (if not, see
Troubleshooting).
8
ti13612a
ti13610a
ti13617a
ti13611a
ti13627a
ti15676a
NOTE: You must be facing the unit and be no more than 10
ft away to learn the controller. The unit can only be
operated by one learned controller at a time.
Secondary Menu - Stored Data
1. Perform Pressure Relief Procedure, see page 6.
2. To access Secondary Menu, make sure flow control
knob is turned fully counter-clockwise to the OFF
position. Then turn power switch on while holding
DTS button down.
ti8793a
3. SERIAL NUMBER scrolls past and then serial num-
ber (e.g. 00001) displays.
ti13622a
4. Short press DTS button and MOTOR HOURS
scrolls past and then total motor run hours are dis-
played.
ti13618a
5. Short press DTS button. LAST ERROR CODE
scrolls by and last error code is displayed (e.g.
E=07). See Electrical Problems, page 19.
ti13601a
ti13667a
ti13605a
ti4266a
ti7362a
ti13619a
ti13615a
ti13607a
3A0245A

Advertisement

Table of Contents
loading

This manual is also suitable for:

258907258906262288262300

Table of Contents