Graco 257100 Operation page 18

Drywall feed pump
Hide thumbs Also See for 257100:
Table of Contents

Advertisement

Troubleshooting
RF Problems
PROBLEM
Unwanted signal will not allow unit
to learn the controller.
RF controller will not learn.
Interference in RF signal
18
CAUSE
Unwanted RF signal. Undesired controller is
active and in close proximity.
Battery is depleted.
Unit has not learned the controller.
Controller RF has been blocked.
Controller is too far away or is not facing the
unit.
Signal is out of range.
SOLUTION
Stop unwanted RF signal by deactivat-
ing the controller. Use BLOCK feature
on Secondary Menu, see page 8.
Replace battery
(CR123A Lithium 3V).
Learn the controller, see page 8.
See CLEAR procedure, page 9.
Move to within 10 ft and face the unit.
Hold the controller away from your
body.
Reposition the unit. Use optional exter-
nal remote antenna.
3A0245A