End Stop; Tape Measure Mounting; Mount For Precision Holder - Bosch EL-52425 Original Instructions Manual

Calibration and adjustment devices
Hide thumbs Also See for EL-52425:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
en
en
20 | EL–52425 | Installation
4.3

End stop

Tighten the screws hand-tight.
1
1
Fig. 4:
End stop
1 2 x M5 x 16
4.4

Tape measure mounting

Fig. 5:
Tape measure mounting
X 0 mm - 300 mm
1. Attach the tape measure mounting at a height of
0 mm - 300 mm (measured from the base plate) or
in accordance with specific vehicle manufacture
requirements.
2. Tighten the screws hand-tight.
|
1 690 386 081
2018-02-22
4.5

Mount for precision holder

i
To simplify assembly, remove the precision holder.
On completion of assembly of the "Mount for the
precision holder", reattach the precision holder.
1. Position the mount for the precision holder on the
threaded bolts of the slide.
2. Fasten the mount for the precision holder to a maxi-
mum of 5 Nm using self-locking hex nuts.
!
A greater torque may damage the threaded bolts.
Fig. 6:
Fastening the mount for the precision holder
Robert Bosch GmbH