BEFORE YOU START

1. Inspect all components prior to installation. If damage is found, please contact your distributor or CellarCool Customer
Service at 1-800-343-9463.
2. The evaporator unit and condensing unit each require a dedicated 115V, 20-amp circuit. Use a surge protector with the unit.
Do not use a GFI (ground fault interrupter) line.
3. The evaporator unit and condensing unit require no communication lines unless the system is equipped with a Cold Weather
Start Kit. If the system is equipped with a Cold Weather Start Kit, a low-voltage 18-2 thermostat wire will need to be run
between the evaporator unit and the condensing unit.
4. A standard 18-5 thermostat wire must be run from the evaporator unit to the thermostat.
5. You are REQUIRED to install a drain line to remove condensation from the evaporator unit.
6. The warranty is not active until a warranty checklist has been received, reviewed, and approved.
7. The system is intended for use in properly designed and constructed wine cellars. Hire a professional wine storage
consultant with a valid contractor's license to build your wine cellar.
8. CellarCool requires that all split systems be installed by a certified HVAC-R technician only. NATE or equivalent is recommended.
If you encounter a problem with your CellarCool system, please refer to the Troubleshooting Guide. If you have any further
questions or concerns, or need technical assistance, please contact CellarCool's Customer Service at 1-800-343-9463. Please be
sure all testing has been completed prior to contacting Customer Service. Please have your results ready for your representative.