CellarCool. Every effort has been made to ensure that the information in this manual is accurate. CellarCool is not responsible for printing or clerical errors.
Using the Manual This manual is intended to assist in the proper installation and maintenance of the CellarCool cooling unit. In order to ensure the longevity of your cooling unit, the equipment should be installed correctly and have a proper care and maintenance schedule.
2. The unit should remain in an upright position for 24 hours prior to operation. 3. The CellarCool unit requires a dedicated 115V, 20-amp circuit. Use a surge protector with the CellarCool unit. Do not use a GFI (ground fault interrupter) line.
CellarCool Customer Service immediately. Please leave the CellarCool unit in its original box until you are ready for installation. This will allow you to move the product safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions.
UNIT SPECIFICATIONS PFD3300 PFD4400 PFD8800 15.75”H x 15.75”W x 37”L (without duct plenums) Dimensions 22.75” H x 15.75” W x 48”L (duct plenums on top of unit) 15.75” H x 22.75” W x 48”L (duct plenums on side of unit) BTUh (with 85°F air 4060...
Insulation Insulation is REQUIRED in order to properly use CellarCool products. It is vital that all walls and ceilings be insulated to keep the cellar temperature as consistent as possible during the summer and winter months. Standard fiberglass or rigid foam insulation is normally used in cellar construction;...
Page 10
In cases where glass doors are used and the room size is close to the recommended system size, the next larger size CellarCool system should be used. This will compensate for the insulation loss due to the lower insulation rating of glass.
Page 11
However, you must have a fresh air inlet as well. Using any other ducting system will void the warranty. Note: If you are unsure whether you have adequate ventilation in your install location, please contact us to assess your specific installation at support@cellarcool.com or 1-800-343-9463. Wine Cellar Mechanical Room Ambient Temperature Factor The cooling unit has the ability to cool a wine cellar efficiently to 55°F as long as the ambient temperature of the area that it is...
BLOWER ORIENTATION INSTRUCTIONS 1. Disconnect power from the unit. 2. Determined the desired location of the blower. NOTE: The Ultimate Plus unit is shipped with the blowers oriented at the top of the unit. If this is your desired orientation, pro- ceed to the plenum installation instructions on page 14.
Page 13
4. Next, disconnect the blower wire (with a Molex connector) located inside the unit, as shown below. 5. Remove the blower from its current location and connect the Molex connector. Ensure that the blower remains in the orienta- tion shown. www.cellarcool.com | Page 11...
REORIENTING THE CONTROLLER BOX NOTE: These instructions only apply when reorienting the evaporator blower to the right. Twist clip 1. First, unclip the wires from the twist clip. 2. Then, using an 11/32" nut driver, remove the two (2) 8-32 Keps nuts securing the transformer to the divider.
Page 15
Ensure that the blower remains in the orientation shown. SIDE VIEW 7. Reinstall the previously removed side panel in the old blower location using screws removed earlier. Use a low torque setting on the drill to avoid stripping the holes. TOP VIEW www.cellarcool.com | Page 13...
PLENUM INSTALLATION Items needed: 16" x 16" x 10" return plenum, 12" x 12" x 8" supply plenum, supplied self-tapping screws, provided insulation NOTE: These instructions apply to both the evaporator and condenser sides of the unit. Insulating the evaporator sup- ply and return plenums before installation is mandatory.
Page 17
3. Seal all seams with foil tape. SUPPLY PLENUM: 1. Fit plenum over exposed flanges. FLANGES Fig. 1 - flange detail Fig. 2 - placement of plenum Pre-drill two (2) 1/8" holes in the locations shown. www.cellarcool.com | Page 15...
Page 18
PLENUM INSTALLATION, CONTINUED 2. Drill two (2) screws through the plenum (using the holes previously drilled in Step 1) to secure it to the unit hous- ing. Use only the provided 5/16" x 1/4" self-tapping screws. 3. Seal all seams with foil tape as shown. PFD 032018 Page 16 | 1-800-343-9463...
PREPARING THE UNIT FOR INSTALLATION The CellarCool unit requires a dedicated 115V, 20-amp circuit. The unit draws a large amount of amps during its initial startup. By designating a dedicated circuit breaker, you will guarantee the unit has enough power to run effectively. Contact an electrician for assistance with the installation of this dedicated electrical circuit.
PRE-INSTALLATION WIRING 1. Remove the six (6) screws securing one of the center access panels on either side of the unit. 2. Insert a standard 18-5 thermostat wire through the small hole on the left side of the face plate as shown below, left. Ultimate Plus 8800 3.
4. Secure the unit to the ceiling joists according to state and local ordinances. NOTE: CellarCool strongly recommends the use of a secondary drain pan with the unit. Install the drain line according to the diagram on page 23.
INSTALLING THE UNIT IN AN ADJACENT ROOM 1. Locate the desired installation location. 2. Mount the unit on a cement platform or some other structure which will keep it off the ground. Make sure that the drain line T-fitting is unobstructed and the drain line can hang down vertically. 3.
DO NOT: • Install through-the-wall return air grilles at floor level where they will collect dust from the floor. • Locate the supply or return air grille where it is blocked by bottles, boxes, or cases. www.cellarcool.com | Page 21...
DUCTING CONFIGURATIONS Fully Ducted Cold Air Supply — Cellar Side Heat Exhaust Return Air — Cellar Side Condenser Intake Attic Mounted Unit It is recommended that you use a condensate pan for this application. NOTE: The condenser intake air must remain between 42°F and 110°F.
Drop a pan tab into the drip tray to prevent the buildup of microbial growth. To prevent mold from growing, allow the drain line to hang above the water line. Expanded Drain Line View Left Side View Right Side View WRONG: Drain line is under water. www.cellarcool.com | Page 23...
ULTIMATE PLUS PFD3300 WITH 24V THERMOSTAT CONVERSION KIT WIRING DIAGRAM WHITE Transformer YELLOW 24V HOT BLACK BLUE BLACK 24V COMMON BLUE BLACK BLUE BLUE Solenoid Relay Relay YELLOW THERMOSTAT LEGEND BLUE Field Installed GREEN YELLOW Factory Installed CRANKCASE HEATER COMPRESSOR...
Relay YELLOW THERMOSTAT LEGEND BLUE Field Installed GREEN YELLOW Factory Installed CRANKCASE HEATER GP12PE MOTOR COMPRESSOR PROTECTOR BLACK WHITE BLACK BLACK BLACK FAN CYCLE SWITCH GREEN GREEN WHITE BLOWER CAPACITOR 4GDSU35 4GDSU35 CONDENSER EVAPORATOR BLOWER BLOWER www.cellarcool.com | Page 25...
ULTIMATE PLUS PFD8800 WITH 24V THERMOSTAT CONVERSION KIT WIRING DIAGRAM WHITE Transformer YELLOW 24V HOT BLACK BLUE BLACK 24V COMMON BLUE BLACK BLUE BLUE Compressor Relay Relay YELLOW THERMOSTAT LEGEND BLUE Field Installed GREEN YELLOW Factory Installed CRANKCASE HEATER WHITE BLACK COMPRESSOR CAPACITOR...
55°F. NOTE: To ensure correct system operation, the 24V thermostat must be placed inside the wine cellar, preferably in a central location away from any airflow. www.cellarcool.com | Page 27...
If so, call Customer Service at 1-800-343-9463. System runs constantly Possible cause Solution Leaky door seal or poorly insulated cellar Fix leaky door seal and insulate cellar in accordance with this manual www.cellarcool.com | Page 29...
Page 32
Unit leaks water Possible cause Solution °) Unit is level System should have a two-degree (2 pitch towards the exhaust side Drain line clogged or kinked Check drain line to make sure water can flow freely Drain is clogged, preventing water from escaping 1.
They are non-corrosive and easy to install. Simply use the access door to drop a pan tab into the drip tray every six weeks. **CellarCool recommends filters with a mean efficiency reporting value (MERV) of 4 or better. Filters are not included with the unit.
TECHNICAL ASSISTANCE CellarCool Customer Service is available Monday through Friday from 6:00 a.m. to 4:00 p.m. Pacific Standard Time. The appointed customer service representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following: •...
A. Two (2) Year Limited Warranty. For the period of TWO (2) YEARS (the “Limited Warranty Period”) from the date of original sale of a Product by CellarCool, if a CellarCool Product is found to be defective in material or workmanship after undergoing CellarCool’s customer service troubleshooting, then, subject to the CellarCool Product Limited...
Page 36
16. No one has any authority to add to or vary the limited warranty on this Product. 3. Product Installation Requirements: A. Prior to installing a CellarCool Product, the End User must read the CellarCool Owner’s Manual and thereafter the End User must follow the required installation, use and maintenance procedures set forth by CellarCool in CellarCool’s Owner’s Manual.
Page 37
D. End User is responsible for all costs incurred for the installation and/or removal of the Product, or any part thereof, unless such cost has been agreed by CellarCool to be a warranty repair prior to the work being performed.
Page 38
Conditions of Sale shall be interpreted as though drafted jointly by CellarCool and Purchaser. Any dispute will be resolved by the courts in and for the County of San Joaquin, State of California, and all parties, CellarCool, Purchaser and End User, hereby irrevocably submit to the personal jurisdiction of such courts for that purpose.
Page 39
CellarCool 1738 E. Alpine Ave Stockton, CA 95205 1-800-343-9463 www.cellarcool.com...