Fillauer MC ProPlus ETD Prosthetist Manual

Fillauer MC ProPlus ETD Prosthetist Manual

Advertisement

Quick Links

MC ProPlus ETD
Prosthetist Manual

Advertisement

loading

Summary of Contents for Fillauer MC ProPlus ETD

  • Page 1 MC ProPlus ETD Prosthetist Manual...
  • Page 2 ), a variety of input sensors, and ® ® high performance. The MC ProPlus ETD can be used with other MC ProPlus components, such as the MC ProWrist Rotator, and easily interchanged with the MC ProPlus Hand, and other manufacturers’ devices.
  • Page 3 This will likely cause damage, additional repairs and void the warranty. Setup Using the User Interface While the default settings in the MC ProPlus ETD may allow the patient to operate the system, it is highly recommended the prosthetist utilize the User Interface to customize the settings for the wearer.
  • Page 4 Quick Disconnect Wrist The Quick Disconnect wrist is a universal design that allows interchangeability with our other terminal devices, such as the MC ProPlus Hand, and other manufacturers’ devices. Instructions for Use Before attaching the MC ETD to the forearm, locate the power switch at the base of the ETD. Ensure it is switched OFF (see diagram, page 3).
  • Page 5 Patient/Prosthetist Controls Upon opening the iOS Application, the user responds as “Patient” or “Prosthetist”. If “Patient” is chosen, many of the adjustments are grayed out. EMG signals are visible for training purposes. Several adjustments such as buzzers, some FLAG adjustments, and Auto-Cal are accessible to the wearer.
  • Page 6 FLAG (Optional) FLAG (Force Limiting, Auto Grasp) is an optional feature for the MC ProPlus Hand and ETD terminal devices. FLAG provides two functions: • Force Limiting, to prevent crushing objects due to excessive pinch force • Auto Grasp, which slightly increases the grip on an object if an inadvertent open signal is detected by the controller Turn FLAG On/Off Upon power up, FLAG is turned off.
  • Page 7: Limited Warranty

    Transport & Storage Temperature: -18° to 71° C (0° to 160° F) Pinch Force: At 7.2 volts nominal: 11 kg (24 lbs, or ~ 107N) Operating Voltage Range: 6 to 8.2 Vdc - MC ProPlus ETD Load Limit: 22 kg / 50 lbs in all directions (+/- 10%)
  • Page 8 • To repeat the tutorial, go to and tap on Reset Guided Tutorial Reset Motion Control, Inc. 115 N Wright Brothers Drive Salt Lake City, UT 84116 801.326.3434 Fax 801.978.0848 www.fillauer.com © 2020 Motion Control, Inc. 1910072 Rev D 08-24-2020...