In the event that the kettle fails to operate correctly,
the difficulty should first be isolated to either the kettle
itself or the steam supply which heats the kettle. While
mechanical problems are obvious faults of the kettle,
any deficiencies in volume and pressure of the steam
should be traced to the steam generator and the cause
determined. Steam input requirements are listed be-
low. This list recommends delivered boiler horsepower
for kettle size and steam flow.
MT6
MT10
MT6T6
MT10T6
MT10T10
LFT6
LFT10
LFT10T6
LFT10T10
CABINET EXTERIOR REMOVAL:
Side and rear panels of all cabinets in which kettles are
mounted are easily removed without the use of tools.
Each panel is grasped at the bottom edge and pulled
out sharply to release it from the panel mounting brack-
ets shown in figure 6 on page 9. Replacement is com-
pleted by pushing panel up under the cabinet top and
pressing in at the bottom until panel mounting brackets
are engaged.
Doors may be removed to improve access to cabinet
interior for repairs as shown in figure 6 on page 9 and
10. The two flat head screws, nuts, and holding cabinet

REPAIR AND REPLACEMENT

1/3 BHP
15-30 PSI
1/2 BHP
15-30 PSI
1/3 BHP
15-30 PSI
1/2 BHP
15-30 PSI
1/2 BHP
15-30 PSI
1 BHP
15-30 PSI
1 BHP
15-30 PSI
1 BHP
15-30 PSI
1 BHP
15-30 PSI
hinge are removed to lift the door out shown in figure
6 on page 9 and 10. When doors are remounted, the
final tightened position of hinge determines the align-
ment of the door and must be set with care, also shown
in figure 6 on page 9 and 10.
TRUNNION MOUNTED KETTLE DISASSEMBLY:
Trunnion mounted kettles may be removed from the
cabinet top for replacement of worn o-rings and lubri-
cation of trunnion parts.
Disassemble as follows:
1.
Disconnect both steam inlet and condensate return
plumbing connected to kettle legs from inside of
cabinet.
2.
Remove 3/8" nuts and washer used to fasten kettle
legs to cabinet top.
3.
Lift kettle with legs attached off of cabinet top.
4.
Insert blade of screwdriver in slots of trunnion end
caps and pry off caps.
5.
Remove retaining rings from ends of trunnions us-
ing retaining ring pliers.
6.
Slip leg and support collar assemblies off of ket-
tle.
7.
Remove o-rings and clean off trunnion parts includ-
ing insides of support collars attached to legs.
8.
Replace o-rings and lubricate trunnion parts with
krylon base no. 1325 silicon spray.
9.
Reassemble kettle and trunnion by completing step
6 and the 5, and tapping end cap back in place (slot
down) with a rubber mallet.
10.
Remount kettle and trunnion assembly on cabinet
top by completing steps 3, 2 and then 1.