Market Forge Industries Universe Plus STGL Series Installation Operation & Maintenance

Gas tilting skillets

Advertisement

UNIVERSE PLUS STGL & STGM SERIES
INSTALLATION - OPERATION - MAINTENANCE
OPEN LEG BASED MODELS
‰ 30P-STGL
‰ 40P-STGL
Telephone: (802) 658-6600 Fax: (802) 864-0183
www.marketforge.com
GAS TILTING SKILLETS
© 2018 - Market Forge
CLOSED BASED MODELS
‰ 30P-STGM
‰ 40P-STGM
PN 14-0384 Rev C (12/18)

Advertisement

Table of Contents
loading

Summary of Contents for Market Forge Industries Universe Plus STGL Series

  • Page 1 UNIVERSE PLUS STGL & STGM SERIES GAS TILTING SKILLETS INSTALLATION - OPERATION - MAINTENANCE OPEN LEG BASED MODELS CLOSED BASED MODELS ‰ 30P-STGL ‰ 30P-STGM ‰ 40P-STGL ‰ 40P-STGM Telephone: (802) 658-6600 Fax: (802) 864-0183 www.marketforge.com PN 14-0384 Rev C (12/18) ©...
  • Page 2 Your Service Agency’s Address: Model Serial number Skillet installed by Installation checked by...
  • Page 3: Table Of Contents

    IMPORTANT TABLE OF CONTENTS WARNING: Improper installa- tion, adjustment, alternation, service or maintenance can INSTALLATION cause property damage, in- Service Connections ........... . . 2 jury or death.
  • Page 4: Service Connections

    Service Connections GAS SUPPLY Supply Pressure (W.C.) Model kW/Hr BTU/Hr Natural Propane 30 gallon 27.2 93,000 7”-14” 11”-14” (178-356mm) (279-356mm) 40 gallon 36.9 126,000 SERVICE CONNECTIONS Gas Connection - Supplied through 3/4” NPT pipe. A gas shut-off valve must be installed in supply piping convenient and adja- cent to appliance.
  • Page 5: Installation Instructions

    Installation Instructions • This unit has a flexible cord wired into electrical CAUTION: BE SURE TO READ! system. • Keep this appliance area free and clear of com- bustibles. GENERAL INSTALLATION 1. Remove carton from skid, being careful not to dent or •...
  • Page 6: Caster Installation

    Installation Instructions d. Propane gas units are equipped with a pressure regulator factory adjusted to give 10” (254mm) water column manifold pressure. The supply pressure must be at least 11” (279mm) water col- umn pressure. e. Maximum supply pressure must not exceed 1/2 PSIG (3.45 kPa) for both natural and propane gas.
  • Page 7: Operating Instructions

    Operating Instructions START-UP PROCEDURE simmering or boiling. The cover has a lip at the rear that will direct condensate into the skillet rather than 1. Open manual gas shut-off valve. onto the cabinet base. 2. Ensure that the braising pan is in the DOWN position. 7.
  • Page 8: Cooking Tips

    Cooking Tips The Universe Plus Skillet is one of the most versatile • The stainless steel Universe Plus skillet is rapidly pieces of equipment to be found in any restaurant or insti- cleaned with a mild detergent. Water, waste, and tution kitchen.This unit will stew, simmer, pan-fry, braise, scraps are easily removed into the receiving pan for grill and saute all with a very uniform heat pattern.
  • Page 9: Suggested Cooking Temperatures

    Suggested Cooking Temperatures 30-Gallon 40-Gallon PORTION THERMOSTAT BATCHES ITEM QTY. PER Gallon QTY. Gallon SIZE SETTING PER HOUR LOAD YIELD PER LOAD YIELD BREAKFAST FOODS Bacon 3 slices 12 lbs. 3 lb. Eggs 1 egg Boiled-Hard 1 egg Boiled-Soft 1 egg Fried 1 egg Poached...
  • Page 10 Suggested Cooking Temperatures 30-Gallon 40-Gallon PORTION THERMOSTAT BATCHES ITEM QTY. PER Gallon QTY. Gallon SIZE SETTING PER HOUR LOAD YIELD PER LOAD YIELD FRANKFURTERS Grilled 22 lb. 33 lb. Boiled 16 lb. 25 lb. POULTRY Chicken, Pan-Fired 2 1/4’s 50 pieces 80 pieces Chicken, Whole 2 oz.
  • Page 11: Cleaning & Maintenance

    Cleaning & Maintenance Test by tilting the pan and checking at what angle the IMPORTANT! switch clicks. The switch should click off at approxi- mately 10E tilt of the pan from the horizontal position. DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING. 5.
  • Page 12: Wiring Diagram

    Wiring Diagram MAINTENANCE...
  • Page 13 Wiring Diagram MAINTENANCE...
  • Page 14: Troubleshooting

    Troubleshooting PROBLEM PROBABLE CAUSE REMEDY 1. Uneven or poor heating. a. Temperature control out of cali- a. Replace temperature control. bration or defective. b. Unit attached to wrong gas b. Compare to specifications on supply. data plate. c. Combination gas control set to c.