Alarm
Alarm
ID
Name
2063
Cabinet
Overte
mperatu
re
2064
Device
Fault
2065
Upgrade
Failed
or
Softwar
e
Version
Unmatc
h
2066
License
Expired
Issue 07 (2020-09-15)
Alarm
Possible Causes
Severit
y
Minor
Cause ID = 1
1. The solar inverter is installed in
a place with poor ventilation.
2. The ambient temperature is
too high.
3. The solar inverter is not
working properly.
Major
Cause ID = 1–15
An unrecoverable fault has
occurred on a circuit inside the
solar inverter.
Minor
Cause ID = 1–4
The upgrade does not complete
normally.
Warnin
Cause ID = 1
g
1. The privilege license has
entered the grace period.
2. The privilege feature will be
invalid soon.
Copyright © Huawei Technologies Co., Ltd.
8 Maintenance
Suggestions
1. Check the ventilation and
whether the ambient
temperature of the solar
inverter exceeds the upper
limit. If the ventilation is
poor or the ambient
temperature is too high,
improve ventilation.
2. If both the ventilation and
ambient temperature meet
requirements yet the fault
persists, contact your
dealer or Huawei technical
support.
Turn off the AC output switch
and DC input switch, and then
turn them on after 5 minutes.
If the fault persists, contact
your dealer or Huawei
technical support.
NOTICE
Cause ID = 1: Perform the
preceding operations when the
PV string current is less than 1 A.
1. Perform an upgrade again.
2. If the upgrade fails for
multiple times, contact
your dealer or Huawei
technical support.
1. Apply for a new license.
2. Load a new license.