6.3 Environmental Considerations

6.3.1 Operating Temperature

Table 6.3.1: Operating
Temperature

6.3.2 Relative Humidity

6.3.3 Vibration and Shock Standards

Acromag, Inc. Tel: 248-295-0310
http://www.acromag.com
Summarized below are the operating temperature range, airflow and other
environmental requirements and applicable standards for the XMC610
Series modules.
MODELS
4-Port RJ45 1GbE NIC XMC
XMC611
4-Port SFP 1GbE NIC XMC
XMC612
4-Port Rear I/O 1GbE NIC XMC
XMC613
1. For applications requiring elevated operating temperatures, a minimum
airflow of 200LFM is recommended.
2. The temperature rating does not apply to the SFP transceiver modules.
Please consult the manufacturer's documentation of the SFP module to
determine its operating temperature range.
The range of acceptable relative humidity is 5% to 95% non-condensing.
The XMC610 series products are designed to comply with the following
Vibration and Shock standards.
Vibration, Random Operating: Designed to comply with VITA 47 Class
V1. Shall withstand vibration from 5 to 100Hz. with Power Spectral
2
Density (PSD) = 0.04g
accordance with MIL-STD-810, Method 514, Procedure 1
Shock, Operating: Designed to comply with VITA 47 Class OS1, 20g,
11ms half sine and terminal sawtooth shock pulses. 3 shock pulses in
each direction along 3 axes (36 shocks, total). Testing shall be in
accordance with MIL-STD-810, Method 516, Procedure 1.
- 16 -
Description
/Hz, for 1 hour per axis. Testing shall be in
- 16 -
USER'S MANUAL
OPERATING
TEMPERATURE RANGE
1
-40C to +85C
1,2
-40C to +85C
1
-40C to +85C