INOR IPAQ C330 Series Manual

INOR IPAQ C330 Series Manual

Smart 2-wire universal transmitter with nfc technology
Table of Contents

Advertisement

IPAQ C330/R330
IPAQ C330/R330
IPAQ C330/R330
IPAQ C330/R330
Smart 2-wire universal transmitter with NFC technology
The documentation is only complete when used in combination with the relevant
documentation for the sensor.
© INOR 01/2019 - 4007317401 – MA IPAQ 330 R01 en

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPAQ C330 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for INOR IPAQ C330 Series

  • Page 1 IPAQ C330/R330 IPAQ C330/R330 IPAQ C330/R330 Smart 2-wire universal transmitter with NFC technology The documentation is only complete when used in combination with the relevant documentation for the sensor. © INOR 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 2 IMPRINT ::::::::::::::::::::::::::::::::::::::: www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 3: Table Of Contents

    5.4 Diagnostic information according to NAMUR NE 107 ........... 29 5.5 Factory default settings....................31 5.6 Sensor error monitoring ....................31 5.7 System or sensor error correction ................31 6 Service 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 4 7.5 Output load diagram....................... 47 7.6 Electrical data for outputs and inputs................48 7.7 RTD and T/C accuracy table ................... 49 8 Appendix 8.1 Installation and control drawings .................. 51 9 Notes www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 5: Safety Instructions

    This device is a Group 1, Class A device as specified within CISPR11. It is intended for use in industrial environment. There may be potential difficulties in ensuring electromagnetic compatibility in other environments, due to conducted as well as radiated disturbances. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 6: Certifications

    II 1 G Ex ia IIC T6...T4 Ga IECEx IECEx KIWA 16.0018X Ex ia IIC T6...T4 Ga See also “ Specific Conditions of Use" in the Ex certificates in the download area of the manufacturer's website www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 7: Safety Instructions From The Manufacturer

    The manufacturer reserves the right to alter the content of its documents, including this disclaimer in any way, at any time, for any reason, without prior notification, and will not be liable in any way for possible consequences of such changes. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 8: Product Liability And Warranty

    This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. Special considerations and precautions are also described in the document, which appear in the form of icons as shown below. www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 9: Warnings And Symbols Used

    In general, devices from the manufacturer may only be installed, commissioned, operated and maintained by properly trained and authorized personnel. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 10: Device Description

    • NFC interface in a portable device such as a smartphone. NFC applies only to later versions of IPAQ 330, see table below . The smartphone app - INOR Connect, makes it possible to read, write, save and share settings directly in the field.
  • Page 11: Nameplate

    Nyyww.xxxxxx KIWA 16ATEX0038 X PO Box 9125 SE-200 39 Malmö PO zzzzzzzzz IECEx KIWA 16.0016X www.inor.com SWEDEN Figure 2-1: Example for round nameplate 1 Product name 2 CE marking (EC conformity) 3 Ex-relevant electrical data and Ex approvals 4 Part number, serial number (yyww = year and week of manufacturing) and batch number...
  • Page 12 No. 4005499601 Ui: 30 V, Ii: 100 mA, Pi: 0.9 W, Ci: 23 nF, Li: 20 μH Uo: 30 V, Io: 54 mA, Po: 405 mW, Co: 38.1 nF, Lo: 11 mH www.inor.com Figure 2-5: Example for nameplate 1 Product name...
  • Page 13: Scope Of Delivery

    II 1 G Ex ia IIC T6...T4 Ga Ui: 30 V, Ii: 100 mA, Pi: 0.9 W, Ci: 23.1 nF, Li: 20 μH Uo: 6.5 V, Io: 11.7 mA, Po: 19.1 mW, Co: 24 μF, Lo: 400 mH www.inor.com Figure 2-6: Example for nameplate 1 Product name...
  • Page 14: Installation

    One way to decrease the head transfer via thermowell is to install the transmitter further away from the heat source. Inversely similar measurements can be done if the temperature gets below specified minimum temperature. www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 15: Rail Mounting Kit For In-Head Transmitters

    2 Screws (not needed) 3 Clip 4 Transmitter Installation procedure: Step 1 1 Place the transmitter on the clip. 2 Press down the transmitter until it is attached to the clip. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 16: Rail-Mount Transmitter

    ° To avoid destruction or damage of the device, always note the following items: Assure that the operating temperature or the ambient temperature does not exceed the • permissible range. www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 17: Electrical Connections

    Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate (applies only to the intrinsically safe versions). 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 18 The transmitter shall be mounted into a suitable enclosure that provides a degree of protection of at least IP20. The NFC Interface for communication must not be used in hazardous areas. www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 19: Electrical Connections Of In-Head Transmitter

    Thermocouple and voltage measurement Thermocouple Thermocouple Thermocouple Thermocouple Voltage Voltage Voltage Voltage Thermocouple with external CJC Thermocouple with external CJC Thermocouple with external CJC Thermocouple with external CJC (Pt100) (Pt100) (Pt100) (Pt100) 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 20: Connection Diagram Of In-Head Transmitter

    For further information refer to Technical data on page Figure 4-1: Connection diagram 1 Voltage supply 8.0…36 VDC (terminals 6, 7) 2 RLoad 3 Input 4 Output 5 Thermocouple 6 Pt100 3-wire connection www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 21: Connection Diagram Of In-Head Transmitter (Intrinsically Safe)

    5 Voltage supply 8.0…30 VDC (intrinsically safe) 6 Output signal (4...20mA) DANGER! The transmitter may be operated in areas with potentially explosive atmospheres if the voltage supply is ensured by means of an associated apparatus. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 22: Electrical Connections Of Rail-Mount Transmitter

    Thermocouple and voltage measurement Thermocouple Thermocouple Thermocouple Thermocouple Voltage Voltage Voltage Voltage Thermocouple with external CJC Thermocouple with external CJC Thermocouple with external CJC Thermocouple with external CJC (Pt100) (Pt100) (Pt100) (Pt100) www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 23: Connection Diagram Of Rail-Mount Transmitter

    2 Classified hazardous area (potentially explosive area e.g. zone 0, 1 or 2) 3 Safe area (intrinsically safe) Load 5 Voltage supply 8,0…30 VDC (intrinsically safe - terminals 21, 22) 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 24: Operation

    The IPAQ 330 include a NFC interface(Applies only to later versions of IPAQ 330, see table on page 10) for communication with a smartphone app - INOR Connect. The configuration procedure uses the NFC function in combination with a smartphone with built-in NFC support to perform all settings of the transmitter.
  • Page 25: Factory Settings For Configuration

    -> Sensor Type of sensor Number of wires PV Lower range value PV Upper range value Digital units °C Damping value 1.2s Sensor break (Off/Downscale/Upscale) Upscale Sensor short circuit Upscale (Off/Downscale/Upscale) 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 26: Configuration With Consoft

    For the applicable ambient temperature range , see the control drawings for C330X/R330X at the end of this book,and for ICON-X - 4006801801 www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 27 5 Connection to USB interface and a PC software ConSoft is not permitted if Ex version of IPAQ C330 (IPAQ C330X) is placed in the classified hazardous area (potentially explosive area) 6 Safe area 7 Classified hazardous area (potentially explosive area e.g. zone 0, 1 or 2) 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 28 6 Connection to the voltage supply during configuration with USB interface and PC software ConSoft is not needed 7 Classified hazardous area (potentially explosive area e.g. zone 0) 8 Classified hazardous area (potentially explosive area e.g. zone 0, 1 or 2) 9 Safe area www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 29: Diagnostic Information According To Namur Ne 107

    No acknowledge from Digital-to-Analog-Converter. Power cycle the device. If error remains replace device. Transmitter System non-recoverable Internal system non-recoverable error. Power cycle the device. If errors error remains replace device. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 30 Transmitter High Alarm Check the sensor and sensor connection. If error remains replace the sensor. Transmitter Low Alarm Check the sensor and sensor connection. If error remains replace the sensor. www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 31: Factory Default Settings

    If the temperature sensor is calibrated, or the sensor error compared to the standard curve is known, then the sensor error (deviation from the standard curve) can be entered into the transmitter via the configuration software and the transmitter corrects for the sensor errors. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 32: Service

    • such dangerous substances, to enclose a certificate with the device confirming that it is safe to handle and stating the • product used. www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 33: Form (For Copying) To Accompany A Returned Device

    6.5.1 Dispose of the transmitter Dispose of the transmitter, sensor and packaging materials in an environmentally compatible way and in accordance with the country-specific waste disposal regulations. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 34: Disassembling And Recycling

    54.8 Stainless steel 14.8 Brass Zinc 7440-66-6 Silicone 7440-21-3 Epoxy 10.2 Lead free solder Nitrile Copper 7440-50-8 Polyester Nickel 7723-14-0 Alumina (Al2O3) 1344-28-1 Gold (Au) 7444-57-6 Barium titanat (BaTiO3) 12047-27-7 www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 35: Disassembling And Recycling Of Ipaq R330/R330X

    IPAQ R330/R330X is not possible except the housing, which is sorted as plastic. The content of the IPAQ IPAQ R330/R330X can be found in the following table. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 36 7439-97-6 Lead (Pb) 7440-31-7 Chrome VI (Cr VI) 7440-47-3 Polybrominated biphenyls (PBB) Bis (2-ethylhexil) phthalate (DEHP) 117-81-7 Butyl benzyl phthalate (BBP) 85-68-7 Dibutyl phthalate (DBP) 84-74-2 Diisobutyl phthalate (DIBP) 84-69-5 www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 37: Packaging Of Ipaq C330/C330X And R330/R330X

    IPAQ C330/R330 6.5.5 Packaging of IPAQ C330/C330X and R330/R330X The products are delivered to the customers in corrugated cardboard boxes, which protect products against moisture and provides sustainable packaging solutions. 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 38: Technical Data

    100 Ω (100 mV / 1 mA = 100 Ω). Figure 7-1: Pt100 resistance temperature sensor in 4-wire connection at 0°C / +32°F, schematic. 1 Pt100 RTD 2 Voltage meter 3 Current source www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 39: Thermocouples

    1 Measuring point t (hot junction) 2 Thermocouple 3 Transition junction t 4 Compensation cable / extension cable 5 Reference junction t (cold junction) 6 Copper conductor 7 Voltage meter U 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 40: Technical Data

    Resistance: ±0.01% < 4000 Ω (2000 Ω at 2-wire) < ±0.02% of span per °C Voltage: ±0.01% of span per °C Supply voltage influence <±0.005% of span per V Long-term drift Max. of ±0.02°C or ±0.02% of span per year www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 41 The upper range depends on the X value, max. input temperature (IEC 60751, α = 0.00385) corresponding to 4000 Ω. Ni100 (DIN 43760) -60...+250°C / -76...+482°F Ni120 (Edison No. 7) 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 42 In-head transmitter: 5 kΩ Field transmitter / Switch room transmitter: 10 kΩ Output Output Output Output Output signal 4...20 mA, 20...4 mA; temperature, resistance or voltage linear, customized linearization possible. www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 43 3.3.0 or later and the firmware in the USB Interface must have a version number 1.2.07 or later. INOR Connect The app INOR Connect for portable devices (smartphones) is a versatile and ® ® user-friendly tool for wireless configuration through Bluetooth or NFC technology.
  • Page 44 R330X (intrinsically safe), partno. 70R330X012 R330X (intrinsically safe), partno. 70R330X012 ATEX KIWA 16ATEX0040 X II 1 G Ex ia IIC T6...T4 Ga IECEx IECEx KIWA 16.0018X Ex ia IIC T6...T4 Ga www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 45: Dimensions

    In-head transmitter Dimensions [mm] [inch] 33.0 1.30 0.28 44.5 1.75 19.7 0.78 Rail-mount transmitter Rail-mount transmitter Rail-mount transmitter Rail-mount transmitter Dimensions [mm] [inch] 17.5 0.69 81.3 3.20 90.0 3.54 1.38 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 46: Temperature Data For Areas With Potentially Explosive Atmospheres

    ≤ +60°C / -40°F ≤ T ≤ +140°F -40°C ≤ T ≤ +75°C / -40°F ≤ T ≤ +167°F -40°C ≤ T ≤ +85°C / -40°F ≤ T ≤ +185°F www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 47: Output Load Diagram

    Formula for the maximum permissible output load: permissible R [Ω] = (U-8.0)/0.022 Load Intrinsically safe transmitter Figure 7-4: Output load diagram X: Power supply U [VDC] Y: Total output load R [Ω] 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 48: Electrical Data For Outputs And Inputs

    Input terminals 1, 2, 3, 4 ≤ 30 VDC ≤ 6.5 VDC ≤ 100 mA ≤ 11.7 mA ≤ 900 mW ≤ 19.1 mW 20 μH 400 mH 24 μF 23.1 nF www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 49: Rtd And T/C Accuracy Table

    ±0.25°C or ±0.2% of span ±0.01% of span per °C T/C type T -270...+400 1 (10 ≤ X ≤ 1000) 2 CJC error not included. ≤ 0.5°C within ambient temperature range 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 50 ±0.9°F or ±0.1% of span ±0.006% of span per °F T/C type T -454...+752 1 (10 ≤ X ≤ 1000) 2 CJC error not included. ≤ 0.9°F within ambient temperature range www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 51: Appendix

    8.1 Installation and control drawings IPAQ Part Number Control drawing C330X 70C330X010 4005488501 C330X 70C330X012 4005488502 R330X 70R330X010 4005499601 R330X 70R330X012 4005499602 1 Without NFC interface 2 With NFC interface 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 52 APPENDIX IPAQ C330/R330 This drawing is property of Inor Process AB, Malmö, Sweden, without whose permission it may not be copied, and the contents thereof must not be imparted to third party nor be used for any unautherized purpose. Contravention will be prosecuted.
  • Page 53 APPENDIX IPAQ C330/R330 This drawing is property of Inor Process AB, Malmö, Sweden, without whose permission it may not be copied, and the contents thereof must not be imparted to third party nor be used for any unautherized purpose. Contravention will be prosecuted.
  • Page 54 APPENDIX IPAQ C330/R330 This drawing is property of Inor Process AB, Malmö, Sweden, without whose permission it may not be copied, and the contents thereof must not be imparted to third party nor be used for any unautherized purpose. Contravention will be prosecuted.
  • Page 55 APPENDIX IPAQ C330/R330 This drawing is property of Inor Process AB, Malmö, Sweden, without whose permission it may not be copied, and the contents thereof must not be imparted to third party nor be used for any unautherized purpose. Contravention will be prosecuted.
  • Page 56 NOTES IPAQ C330/R330 www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 57 NOTES IPAQ C330/R330 01/2019 - 4007317401 – MA IPAQ 330 R01 en www.inor.com...
  • Page 58 NOTES IPAQ C330/R330 www.inor.com 01/2019 - 4007317401 – MA IPAQ 330 R01 en...
  • Page 59 Products that are covered by the Limited Warranty will either be repaired or replaced at the option of INOR. Customer pays freight to INOR, and INOR will pay the return freight by post or other ”normal” way of transport. If any other type of return freight is requested, customer pays...
  • Page 60 Phone: +49-(0)203 7382 762 0 Fax: +1 978 535 1720 Fax: +358-(0)10-4217901 Fax: +49-(0)203 7382 762 2 E-mail: inor-info@krohne.com E-mail: myynti@inor.fi E-mail: info@inor-gmbh.de Web: www.inor.com Web: www.inor-gmbh.de Web: www.krohne-inor.fi The current list of all INOR contacts and addresses can be found at: www.inor.com...

Table of Contents