A5MSX-2009 Table of Contents Table of Contents Nomenclature........................1 Indoor Unit ........................1 Outdoor Unit ........................2 Product Line-Up ......................3 Features..........................5 Application Information .....................6 Operating Range ......................6 Refrigerant Circuit Diagram ...................7 Controller ........................10 Installation Guideline ....................11 Engineering & Physical Data ..................24 General Data ......................
Nomenclature A5MSX-2009 Nomenclature Indoor Unit Brand : Acson Refrigerant : R410A Model Name : Wall Mounted Inverter System Type : X series Capacity Index : 10,000 Btu/h : 15,000 Btu/h : 20,000 Btu/h Chassis : G series Model Type “ ”...
A5MSX-2009 Nomenclature Outdoor Unit Brand : Acson Refrigerant : R410A Model Name : Multi Split Condensing Unit Inverter System Type : X series Capacity Index : 20,000 Btu/h : 25,000 Btu/h : 30,000 Btu/h Chassis : A series Model Type “...
Features A5MSX-2009 Features Self Diagnosis The microprocessor provides the possibility to detect and diagnose any fault or malfunction that occurs in the system. The error will be reflected by the blinking of the LED lights. Advance Technology Incorporating fuzzy logic control enables greater flexibility in system control handling to achieve •...
A5MSX-2009 Application Information Application Information Operating Range Ensure the operating temperature is in allowable range. Cooling Only Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. Indoor temp. (°C WB) Heatpump Heating Cooling...
A5MSX-2009 Application Information Controller SLEEP MODE TIMER TIMER TIMER CANCEL Operation Guide Transmission Source Operating Mode • The source where the signal will be transmitted. • Press the MODE button to select the type of operating mode. Signal Transmission Indication •...
Application Information A5MSX-2009 Installation Guideline Safety Precautions WARNING CAUTION • Installation and maintenance should be performed by Please take note of the following important points qualifi ed persons who are familiar with local code and when installing. regulation, and experienced with this type of appliance. •...
Page 15
A5MSX-2009 Application Information Installation of Indoor Unit The indoor unit must be installed in such a way so as to prevent short circuit of the cool discharged air with the hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit where there could be direct sunlight shinning on it.
Page 16
Application Information A5MSX-2009 Mounting Installation Plate Ensure that the wall is strong enough to withstand the weight of the unit. Otherwise, it is necessary to reinforce the wall with plates, beams or pillars. Use the level gauge for horizontal mounting, and fix it with 4 suitable screws. In case the rear piping draws out, drill a hole 65mm in diameter with a cone drill, slightly lower on the outside wall (see figure) Screw position in the wall...
Page 17
A5MSX-2009 Application Information Indoor unit combination for outdoor unit A5MSX20A/AR, A5MSX25A/AR and A5MSX30A/AR Indoor units with model name A5WMX10G/GR, A5WMX15G/GR and A5WMX20G/GR could be coupled with this outdoor unit. The following table shows the possible coupling combinations available. Coupling Combinations (5WMX-G/GR) A5MSX20A/AR A5MSX25A/AR A5MSX30A/AR...
Page 18
Application Information A5MSX-2009 Installation Of Outdoor Unit The outdoor unit must be installed in such a way, so as to prevent short circuit of the hot discharged air or obstruction to the smooth air flow. Please follow the installation clearance shown in the figures below. Select the coolest possible place where intake air temperature is not greater than the outside air temperature (maximum 45°C/113°F).
Page 19
A5MSX-2009 Application Information Refrigerant Piping Work Piping Length and Elevation If the pipe is too long, both capacity and reliability of the unit will drop. As the number of bends increases, resistance to the flow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective.
Page 20
Application Information A5MSX-2009 Piping Work • Do not use contaminated or damaged copper tubing. Do not remove plastic, rubber plugs and brass nuts from the valves, fittings, tubings and coils until you are ready to connect suction or liquid line into valves or fittings.
Page 21
A5MSX-2009 Application Information Piping Connection To The Units • The outdoor unit is equipped with two to four sets of flare joints depending on O/D unit model. Refer to table below for flare joint size and location. • In the case where gas pipe from the indoor unit does not match the outdoor flare joints, two different flare joint connectors are provided.
Page 22
Application Information A5MSX-2009 Electrical Wiring Connection IMPORTANT : The figures shown in the table are for information purpose only. They should be checked and selected to comply with the local/national codes of regulations. This is also to the type of installation and conductors used.
Page 23
A5MSX-2009 Application Information Wire Clamp Interconnection Cable Power Supply Cable A5WMX10G/15G A5WMX20G/GR Model Voltage range 220V-240V / 1 Ph / 50Hz + Power supply cable size (mm Number of wire Interconnection cable size (mm Number of wire Recommended time delay fuse for O/D unit •...
Page 24
Application Information A5MSX-2009 Vacuuming And Charging Purging The Piping And Indoor Unit Except for the outdoor unit which is pre-charged with refrigerant R22, the indoor unit and the refrigerant connection pipes must be air-purged because the air containing moisture that remains in the refrigerant cycle may cause malfunction of the compressor.
Page 25
A5MSX-2009 Application Information Charge operation This operation must be done by using a gas cylinder and a precise weighing machine. The additional charge is topped up into the outdoor unit using the suction valve via the service port. • Remove the service port cap. •...
Page 26
Application Information A5MSX-2009 Indicator Lights IR Signal Receiver When an infrared remote control operating signal has been transmitted, the signal receiver on indoor unit will made a (beep) sound to comfirm acceptance of the signal transmission. The table shows the LED indicator lights for the indoor air conditioner unit under normal operation and fault conditions.
A5MSX-2009 Engineering & Physical Data Engineering & Physical Data General Data - Cooling Only OUTDOOR UNIT A5MSX20A MODEL A5WMX10G A5WMX15G INDOOR UNIT Btu/h 19000 19000 NOMINAL CAPACITY 5570 5570 NOMINAL TOTAL INPUT POWER 1500 1500 NOMINAL RUNNING CURRENT 6.75 6.75 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50...
Page 28
Engineering & Physical Data A5MSX-2009 General Data - Cooling Only OUTDOOR UNIT A5MSX25A MODEL INDOOR UNIT A5WMX10G A5WMX15G Btu/h 22000 22000 NOMINAL CAPACITY 6450 6450 NOMINAL TOTAL INPUT POWER 1815 1815 NOMINAL RUNNING CURRENT 8.13 8.13 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 REFRIGERANT TYPE R410A...
Page 29
A5MSX-2009 Engineering & Physical Data General Data - Cooling Only OUTDOOR UNIT A5MSX25A MODEL INDOOR UNIT A5WMX20G Btu/h 22000 NOMINAL CAPACITY 6450 NOMINAL TOTAL INPUT POWER 1815 NOMINAL RUNNING CURRENT 8.13 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 REFRIGERANT TYPE R-410A HIGH...
Page 30
Engineering & Physical Data A5MSX-2009 General Data - Cooling Only OUTDOOR UNIT A5MSX30A MODEL INDOOR UNIT A5WMX10G A5WMX15G A5WMX20G Btu/h 26000 26000 26000 NOMINAL CAPACITY 7620 7620 7620 NOMINAL TOTAL INPUT POWER 2350 2350 2350 NOMINAL RUNNING CURRENT 10.44 10.44 10.44 POWER SOURCE V/Ph/Hz...
Page 31
A5MSX-2009 Engineering & Physical Data General Data - Heatpump A5MSX20AR OUTDOOR UNIT MODEL A5WMX10GR A5WMX15GR INDOOR UNIT Btu/h 19000 19000 NOMINAL COOLING CAPACITY 5570 5570 Btu/h 21000 21000 NOMINAL HEATING CAPACITY 6150 6150 NOMINAL TOTAL INPUT POWER (COOLING) 1500 1500 NOMINAL TOTAL INPUT POWER (HEATING) 1630 1630...
Page 32
Engineering & Physical Data A5MSX-2009 General Data - Heatpump OUTDOOR UNIT A5MSX25AR MODEL INDOOR UNIT A5WMX10GR A5WMX15GR Btu/h 22000 22000 NOMINAL COOLING CAPACITY 6450 6450 Btu/h 25000 25000 NOMINAL HEATING CAPACITY 7330 7330 NOMINAL TOTAL INPUT POWER (COOLING) 1815 1815 NOMINAL TOTAL INPUT POWER (HEATING) 1900 1900...
Page 33
A5MSX-2009 Engineering & Physical Data General Data - Heatpump OUTDOOR UNIT A5MSX25AR MODEL INDOOR UNIT A5WMX20GR Btu/h 22000 NOMINAL COOLING CAPACITY 6450 Btu/h 25000 NOMINAL HEATING CAPACITY 7330 NOMINAL TOTAL INPUT POWER (COOLING) 1815 NOMINAL TOTAL INPUT POWER (HEATING) 1900 NOMINAL RUNNING CURRENT (COOLING) 8.13 NOMINAL RUNNING CURRENT (HEATING)
Page 34
A5MSX-2009 Engineering & Physical Data General Data - Heatpump OUTDOOR UNIT A5MSX30AR MODEL A5WMX10GR A5WMX15GR A5WMX20GR INDOOR UNIT Btu/h 26000 26000 26000 NOMINAL COOLING CAPACITY 7620 7620 7620 Btu/h 28000 28000 28000 NOMINAL HEATING CAPACITY 8210 8210 8210 NOMINAL TOTAL INPUT POWER (COOLING) 2350 2350 2350...
A5MSX-2009 Engineering & Physical Data Components Data - Cooling Only OUTDOOR UNIT A5MSX20A MODEL A5WMX10G A5WMX15G INDOOR UNIT TYPE ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER...
Page 36
Engineering & Physical Data A5MSX-2009 Components Data - Cooling Only OUTDOOR UNIT A5MSX25A MODEL A5WMX10G A5WMX15G INDOOR UNIT TYPE ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER...
Page 37
A5MSX-2009 Engineering & Physical Data Components Data - Cooling Only OUTDOOR UNIT A5MSX25A MODEL INDOOR UNIT A5WMX20G TYPE ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION INDOOR FAN...
Page 38
Engineering & Physical Data A5MSX-2009 Components Data - Cooling Only OUTDOOR UNIT A5MSX30A MODEL INDOOR UNIT A5WMX10G A5WMX15G A5WMX20G TYPE ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN...
Page 39
A5MSX-2009 Engineering & Physical Data Components Data - Heatpump INDOOR UNIT A5MSX20AR MODEL A5WMX10GR A5WMX15GR OUTDOOR UNIT TYPE ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in...
Page 40
Engineering & Physical Data A5MSX-2009 Components Data - Heatpump OUTDOOR UNIT A5MSX25AR MODEL INDOOR UNIT A5WMX10GR A5WMX15GR TYPE ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in...
Page 41
A5MSX-2009 Engineering & Physical Data Components Data - Heatpump A5MSX25AR OUTDOOR UNIT MODEL INDOOR UNIT A5WMX20GR TYPE ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION INDOOR FAN...
Page 42
Engineering & Physical Data A5MSX-2009 Components Data - Heatpump A5MSX30AR OUTDOOR UNIT MODEL INDOOR UNIT A5WMX10GR A5WMX15GR A5WMX20GR TYPE ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE INDOOR FAN DRIVE...
Electrical Data A5MSX-2009 Electrical Data Electrical Data - Cooling Only A5MSX20A OUTDOOR UNIT MODEL INDOOR UNIT A5WMX10G A5WMX15G INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT...
Page 51
A5MSX-2009 Electrical Data Electrical Data - Cooling Only A5MSX25A OUTDOOR UNIT MODEL INDOOR UNIT A5WMX10G A5WMX15G INSULATION GRADE CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.19...
Page 52
Electrical Data A5MSX-2009 Electrical Data - Cooling Only OUTDOOR UNIT A5MSX25A MODEL INDOOR UNIT A5WMX20G INSULATION GRADE CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.31 MOTOR OUTPUT POLES INSULATION GRADE CLASS B...
Page 53
A5MSX-2009 Electrical Data Electrical Data - Cooling Only A5MSX30A OUTDOOR UNIT MODEL A5WMX10G A5WMX15G A5WMX20G INDOOR UNIT INSULATION GRADE CLASS E CLASS E CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR...
A5MSX-2009 Service and Maintenance Service and Maintenance Service Parts Maintenance Procedures Period At least once every 1. Remove any dust adhering to the filter by using a vacuum 2 weeks. cleaner or wash in lukewarm water (below 40°C) with a neutral cleaning detergent.
Page 58
Service and Maintenance A5MSX-2009 Electrostatic Filter Dual Action Electrostatic Air Purifying and Deodorizing Filter Media and Filter Frame Action 1- Action 2- Electrostatic air purifying filter Deodorizing filter Removes microscopic dust, smoke and Remove unwanted smells and odors in small invisible particules to keep the room the air and keepsthe room air fresh with air clean with pre-charged electrostatic activated carbon filter.
A5MSX-2009 Troubleshooting Troubleshooting If there is any malfunction of the air conditioner unit detected, please switch off the main power supply immediately before proceeding with the following troubleshooting procedures as safety precautions.The following are some common fault conditions and simple troubleshooting tips. If encounter any faulty conditions which are not listed, please contact nearest dealer or service maintenance.
Page 60
Troubleshooting A5MSX-2009 Normal Running Mode Condition If the air conditioner unit has no faulty indications and the compressor is running at normal mode, the outdoor P.C. Board’s LED indication will blink at a slower pace. The table below shows the significant meaning of different running mode and limitation for this air conditioner unit.One must not attempt to see the LED indication blinking unless instructed to do so.
Page 61
A5MSX-2009 Troubleshooting Troubleshooting Progress If the air conditioner is not operating normally, One should follow the troubleshooting steps as stated in the flow chart below Keep the Main Power Supply ON Open up the Outdoor Note: Unit’s Top Panel or DO NOT TOUCH ANY OF THE WIRES OR Service Panel CONNECTIONS IN THE CONTROL BOX...
Page 62
Troubleshooting A5MSX-2009 Check Point (3) – IPM Board Step-by-step troubleshooting guide for identifying IPM Board error. Check Point (3) Check IPM Board Use Multi Meter Check Connectivity Between +ve and U, Check DC Voltage V and W Terminals Input ~300Vdc Change Check Wiring DC Voltage...
A5MSX-2009 Exploded View and Part List Exploded View and Part List INDOOR UNIT MODEL : A5WMX10/15G/GR No Description Part Number Description Part Number Assy. Chassis R50124064151 Assy. Front Cover A R50124085074 Motor, Blower R03039022520 Assy. Air Discharge R50124062326 Blower R03029019461 Air Filter R12014062321 Bush, Fan...
Page 64
Exploded View and Part List A5MSX-2009 INDOOR UNIT MODEL : A5WMX20G/GR No Description Part Number Description Part Number Assy. Chassis R50124068170 Assy. Front Cover A R50124074743 Motor, Blower R50034074747 Assy. Air Discharge R50124071426 Blower R03029029158 Air Filter Bush, Fan R11014023775 Nanosilver R12014080142 Assy.
Page 65
A5MSX-2009 Exploded View and Part List OUTDOOR UNIT MODEL : A5MSX20A/AR Description Part Number No Description Part Number Assy. Base Pan R50014073830 Valve Cover R12014057544 Assy. Outdoor Coil R50024071636 Front/Left Panel R01014070947 Panel, Partition R01014072818 Right Back Panel R01014070950 Assy. Compressor R50049024264 Top Panel R01014070596...
Page 66
Exploded View and Part List A5MSX-2009 OUTDOOR UNIT MODEL : A5MSX25A/AR No Description Part Number No Description Part Number Assy. Base Pan Bracket, Fan Motor R01014070948 R50014081766 Assy. Mounting Plate, Fan Motor R03039024771 R50014081839 Compressor Fan Blade R03019023393 Assy. Outdoor Coil R50024082873 Front/Left Panel R01014070947...
Page 67
A5MSX-2009 Exploded View and Part List OUTDOOR UNIT MODEL : A5MSX30A/AR No Description Part Number No Description Part Number Assy. Base Pan R50014081766 15 Fan Motor R03039024771 Assy. Mounting Plate, Compressor R50014081839 16 Fan Blade R03019023393 Assy. Outdoor Coil R50024082173 17 Front/Left Panel R01014070947 Panel, Partition...
Page 68
While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of specifications and equipment are also subject to change to suit local conditions and requirements and not all models are available in every market.