1. NOMENCLATURE Outdoor Product Specification Variation Type of Connection F : Flare Connection Electrical Characteristic A : 220 – 240V/1Ph/50Hz F : 380 – 415V/3Ph/50Hz Series A : A Series Capacity 10 : 10,000 Btu/h Model Name WSS : Water Source Single Split Brand A : Acson...
Page 4
Indoor Product Specification Variation Type of Connection F : Flare Connection Electrical Characteristic A : 220 – 240V/1Ph/50Hz Series C : C Series Capacity 10 : 10,000 Btu/h Model Name CC: Ceiling Concealed Brand A : Acson...
Page 5
Product Specification Variation Type of Connection F : Flare Connection Electrical Characteristic A : 220 – 240V/1Ph/50Hz Series A : A Series C : C Series Capacity 10 : 10,000 Btu/h Model Name CK: Ceiling Cassette Brand A : Acson...
Page 6
Others E: Fifth Generation Grille C: Grille C B: Grille B A: Grille A Air Devices Treatment & Control I : Negative Ion with wireless controller N: NTP with wireless controller X: Oxygen unit Market Region C : Export with CE marking Electrical Characteristic A : 220-240V/1Ph/50Hz Series...
Page 7
A : First Issue Other Specifications I : Ionizer Generator N : Non Thermal Plasma Controller Specifications G : Wireless Handset S : SLM3 N : Netware III Market Region C : Export with CE mark Electrical A : 220-240V/1Ph/50Hz Series E : E series Capacity...
2. FEATURES Acson Water Source Single Split (AWSS) system is one of the most efficient and high performance systems that can move energy in a building from where it is not needed to where it is needed. It is perfect for buildings that required heating and cooling operation at different zones.
Controller SENSOR ON/OFF AUTO COOL HIGH TEMP MODE HEAT TIMER SWING SLEEP Temperature Setting Temperature (Seven Segments) • Set the desired temperature. • To indicate the ambient temperature set by the user. • Press ▲ or ▼ button to increase or decrease the set temperature.
Page 15
6a 6b SLEEP MODE TIMER TIMER TIMER CANCEL Operation Guide 1. Transmission Source • The source where the signal will be transmitted. 2. Signal Transmission Indication • Blink to confirm that the last setting has been transmitted to the unit. 3.
Page 16
5. Automatic Air Swing (optional) Press the SWING button to activate the automatic air swing function. To distribute the air to a specific direction, press the SWING button and wait until the louver move to the desired direction and press the button once again. 6a.
Page 17
OPERATING STATE AND FAULT TABLE CEILING CONCEALED FAN COIL UNIT WIRED REMOTE CONTROL Cooling Only Model (L208 PCB) Error Code at 7 Segment Display Operation / Faulty Indication n i l r open or short n i l r open n i l r open n i l...
Page 18
WIRED REMOTE CONTROL Cooling Model Error Code at 7 Segment Display Operation / Faulty Indication n i l r open or short n i l r open n i l r open n i l d/ Indoorr coil sensor short/ Outdoor Coil sensor short n i l n i l...
Page 19
Installation Installation for outdoor unit AWSS Location Both the units are not designed for outdoor installation. Install these units at the INDOOR area that provide easy piping connections and enough space for service or repair works. The area or ceiling must be able to withstand the unit weight and is isolated from noise and vibration.
Water Loop Piping The piping connected to the units has to be firmly secured and properly sealed. It is recommended that flexible hoses be used to connect water piping to the unit. It will reduce or eliminate noise transmission (if any) to the main water piping.
Installation For Indoor Unit ACC Preliminary Site Survey Electrical supply and installation is to conform to local authority’s codes and regulations. (e.g. National Electricity Board). Voltage supply fluctuation must not exceed +/- 10% of rated voltage. Electricity supply lines must be independent of welding transformers which can cause high supply fluctuation. Ensure that the location is convenient for wiring and piping.
Installation For Indoor Unit ACK Preliminary Site Survey • Electrical supply and installation is to conform to local authority’s (e.g. National Electrical Board) codes and regulations. • Voltage supply fluctuation must not exceed ± 10% of rated voltage. Electricity supply lines must be independent of welding transformer which can cause high supply fluctuations.
Unit Hanging INDOOR UNIT Ceiling Board 35.0 mm (ACK-A) 30.0mm (ACK-C) • Confirm the pitch of the hanging rod is 790.0mm x 620.5mm(ACK-A) and 505.0mm x 538.0mm (ACK-C). • Hold the unit and hang it on the hanging rod with the nut and washer. •...
Panel Installation • The front panel can only be fitted in one direction, follow the piping direction. (Follow piping arrow sticker on front panel). • Be sure to remove the installation template before installing the front panel. • Open the air intake grille by pulling back the catchers and remove it together with filter from panel. •...
Page 25
Short Duct Specification Applicable for ACK-A Series Only The indoor unit is provided with air discharge and air intake “knock-out” hole for duct connection. However • the connection of the short duct for air discharge is possible on only one side. The use of short duct for air discharge will improve air flow distribution if there is an obstruction (such as •...
Page 26
Fresh Air Intake for ACK-C Unit Take off the panel from the indoor unit Figure 1 Remove the PE foam from the drain pan and another one on the unit. Remove the pre-punched panel on the CKC unit with a screwdriver.
Page 27
Figure 3 The direction of the fresh air intake is shown as figure 3. Sealing Material It is possible to seal one of the four air discharge outlet (sealing two or more air discharge outlet • could cause a malfunction). Remove the front panel and inserting the seal material into the air discharge outlet at the indoor unit to •...
Page 28
Installation For Indoor Unit AWM Location and Space The indoor unit must be installed in such a wayso as to prevent short circuit of the cooldischarged air with the hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit where there could be direct sunlight shining on it.
Page 29
Mounting Installation Plate Ensure that the wall is strong enough to with stand the weight of the unit. Otherwise, it is necessary to reinforce the wall with plates, beams or pillars. Use the level gauge for horizontal mounting, and fix it with 4 suitable screws.
Refrigerant Piping Copper Pipe Connection Do not use contaminated, dented or used copper tubing. Do not use copper tubes with less than 0.8mm thickness. Remove burns from cut edges of the pipes with remover. Hold the end of the pipe downwards to prevent metal chips from entering the pipe.
Page 31
flow increase thus lowering the capacity of the unit and as a result the compressor may become defective. Always choose the shortest path and follow the recommendation as tabulated below. AWSS30A AWSS40A AWSS50A AWSS60A Max Length, L Max.
1/1 Octave Sound Pressure Level (dB, reference 20µPa) Overall Model Noise Criteria (dBA) 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz AWSS30A AWSS40A AWSS50A AWSS60A Sound Power 1/1 Octave Sound Power Level (dB, reference 1pW) Overall Model (dBA) 125Hz 250Hz 500Hz...
Page 33
Ceiling Concealed Fan Coil Unit (R22) Sound Pressure 1/1 Octave A-weighted Sound Pressure (dBA), ref 20µPa Ext. Static Overall Noise Model Speed (mmAq) 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz A (dBA) Criteria Super High High ACC 30C Medium Super High High ACC 40C Medium...
Page 34
Sound Power 1/1 Octave A-weighted Sound Power (dB), ref 1pW Ext. Static Overall Speed Model A (dBA) (mmAq) 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Super High High ACC 30C Medium Super High High ACC 40C Medium Super High High ACC 50C Medium Super High...
Page 35
Ceiling Casette Fan Coil Unit (R22) Sound Pressure Level ACK-A Series 1/1 Octave A-weighted Sound Pressure (dBA), ref 20µPa Overall Noise Model Speed 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz A (dBA) Criteria High ACK 20A Medium High ACK 25A Medium High ACK 30A...
6. ENGINEERING & PHYSICAL DATA General Data - Cooling only unit (R22) INDOOR UNIT ACC 30 CC 40C MODEL OUTDOOR UNIT AWSS 30 WSS 40A Btu/h 2709 0755 NOMINAL COOLING CAPACITY 7940 11945 NOMINAL TOTAL INPUT POWER 2220 3050 NOMINAL RUNNING CURRENT 12.2 POWER SOURCE V/Ph/Hz...
Page 48
General Data - Cooling only unit (R22) INDOOR UNIT ACC 50C ACC 60C MODEL OUTDOOR UNIT AWSS 50A AWSS 60A Btu/h 48450 53675 NOMINAL COOLING CAPACITY 14200 15730 NOMINAL TOTAL INPUT POWER 3650 4430 NOMINAL RUNNING CURRENT 6.80 7.90 POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 3.89...
Page 49
General Data - Cooling only unit (R22) INDOOR UNIT ACK 30A MODEL OUTDOOR UNIT AWSS 30A Btu/h 29800 NOMINAL COOLING CAPACITY 8730 NOMINAL TOTAL INPUT POWER 2300 NOMINAL RUNNING CURRENT 12.04 POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 3.80 REFRIGERANT TYPE REFRIGERANT CONTROL INDOOR CAP TUBE...
Page 50
General Data - Cooling only unit (R22) INDOOR UNIT ACK 40A ACK 50A MODEL OUTDOOR UNIT AWSS 40A AWSS 50A Btu/h 37200 46200 NOMINAL COOLING CAPACITY 10903 13540 NOMINAL TOTAL INPUT POWER 2900 3672 NOMINAL RUNNING CURRENT 5.41 6.91 POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 3.76...
Page 51
Components Data (R22) INDOOR UNIT ACC 30C ACC 40C MODEL OUTDOOR UNIT AWSS 30A AWSS 40A TYPE CENTRIFUGAL Q'TY MATERIAL GALVANIZED STEEL INDOOR FAN DRIVE DIRECT DIAMETER mm/in 214 / 8.43 LENGTH mm/in 203.2 / 8.00 TYPE INDUCTION INDOOR FAN Q'TY MOTOR INDEX OF PROTECTION (IP)
Page 52
Components Data (R22) INDOOR UNIT ACC 50C ACC 60C MODEL OUTDOOR UNIT AWSS 50A AWSS 60A TYPE CENTRIFUGAL Q'TY MATERIAL GALVANIZED STEEL INDOOR FAN DRIVE DIRECT DIAMETER mm/in 214 / 8.43 LENGTH mm/in 203.2 / 8.00 TYPE INDUCTION INDOOR FAN Q'TY MOTOR INDEX OF PROTECTION (IP)
Page 53
Components Data (R22) INDOOR UNIT ACK 30A MODEL OUTDOOR UNIT AWSS 30A TYPE TURBO FAN Q'TY MATERIAL ASG20 INDOOR FAN DRIVE DIRECT DIAMETER mm/in 450 / 17.72 LENGTH mm/in 169.5 / 6.67 TYPE INDUCTION INDOOR FAN Q'TY MOTOR INDEX OF PROTECTION (IP) IP22 TYPE ROTARY...
Page 54
Components Data (R22) INDOOR UNIT ACK 40A ACK 50A MODEL OUTDOOR UNIT AWSS 40A AWSS 50A TYPE TURBO FAN Q'TY MATERIAL ASG20 INDOOR FAN DRIVE DIRECT DIAMETER mm/in 450 / 17.72 LENGTH mm/in 169.5 / 6.67 TYPE INDUCTION INDOOR FAN Q'TY MOTOR INDEX OF PROTECTION (IP)
9. ELECTRICAL DATA Cooling only (R22) INDOOR UNIT ACC 40C ACC 50C MODEL OUTDOOR UNIT AWSS 40A AWSS 50A INSULATION GRADE CLASS E POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 1.98 2.26 MOTOR OUTPUT...
11. SERVICING & MAINTENANCE Warning Disconnect from Main Supply before Servicing the air conditioner The unit is designed to give a long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. start-up and periodic data is useful as indicator of general condition of equipment.
12. TROUBLESHOOOTING When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer.
13. EXPLODED VIEW & PART LIST Indoor Unit Model: AWSS30A Description Description Assy., Base Pan Panel, Service Rubber Grommet Assy., Panel Left Compressor Panel, Top Assy., Valve Plate Assy., Control Box Valve, Flare 3/8" Assy., Cover Control Box Valve, Flare 5/8"...
Page 70
Indoor Unit Model: AWSS40/50/60A Description Description Assy., Base Pan Assy., Panel Right Assy., Tube in Tube Main Panel, Service Compressor Panel, Top Accumulator Bush, Rubber Valve, Flare 3/8" Assy., Hanging Bracket Valve, Flare 3 Way 3/4" Assy., Control Box Assy., Tube Discharge Assy., Control Box Cover Tube Gas Parts not in Diagram...
Page 71
Indoor Unit Model: ACC10C Parts Not in Diagram Description Cabinet Assy., Wheel & Housing Fan Deck Fan Motor Assy., Coil Air Filter Primary Drain Pan Assy., Drain Pipe Joint Secondary Drain Pan L2 Control Module Hanger Handset ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE...
Page 72
Indoor Unit Model: ACC15/20C Description Parts Not in Diagram Cabinet Assy., Wheel & Housing - Left Fan Deck Assy., Wheel & Housing - Right Assy., Coil Fan Motor Primary Drain Pan Air Filter Secondary Drain Pan Assy., Drain Pipe Joint Hanger L2 Control Module Handset...
Page 73
Indoor Unit Model: ACC30C Front View Front View Description Description Assy., Top Panel Filter Rail Parts not in Diagram Assy., Coil Hanger Assy., Drain Pan (Small) Fan Motor Assy., Drain Pan (Big) Bracket, Motor Assy., Wheel & Housing - Left Support, Bracket Motor Assy., Wheel &...
Page 74
Indoor Unit Model: ACC40C Front View Description Description Assy., Top Panel Filter Rail Parts not in Diagram Assy., Coil Hanger Assy., Drain Pan (Small) Fan Motor Assy., Drain Pan (Big) Bracket, Motor Assy., Wheel & Housing - Left Support, Bracket Motor Assy., Wheel &...
Page 75
Indoor Unit Model: ACC50C Front View Description Description Assy., Top Panel Filter Rail Parts not in Diagram Assy., Coil Hanger Assy., Drain Pan (Small) Fan Motor Assy., Drain Pan (Big) Bracket, Motor Assy., Wheel & Housing - Left Support, Bracket Motor Assy., Wheel &...
Page 76
Indoor Unit Model: ACC60C Front View Description Description Assy., Top Panel Filter Rail Parts not in Diagram Assy., Coil Hanger Assy., Drain Pan (Small) Fan Motor Assy., Drain Pan (Big) Bracket, Motor Assy., Wheel & Housing - Left Support, Bracket Motor Assy., Wheel &...
Page 77
Indoor Unit Model: ACK-A (R22) Description Description Base Pan Level Switch Fan Motor Coil Support Fan Motor Bush Partition Side Panel Front Plain Washer Fan Motor Washer Valve Plate Bottom Coupling Drain Connector Turbo Fan Side Panel Back Top Coupling Air Guide Flat Washer Drain Pan...
Page 78
Indoor Unit Model: ACK-A Panel Description Description Front Frame Panel Swing Motor Receiver Bracket Swing Motor Bracket Discharge Housing A Panel Cover Assy., Louver A Fix Plate Discharge Housing B Air Intake Grille Assy., Louver B Grille Lock Discharge Housing D Grille Lock Bracket Louver Bracket Air Filter...
Page 79
Indoor Unit Model: ACK-C Description Description Assy., Base Pan Assy., Drain Pump Support Bracket Assy., Casing Assy., End Plate Support Assy., Coil Clip, Coil Sensor Fan Cover Tube, Coil Sensor Holder Turbo Fan Bracket, Coil Plate, Wire Cover, Terminal Fan Motor Cover, Wire Bush, Fan Motor Drain Connector...
Page 80
Indoor Unit Model: ACK-C Panel Description Description Frame Assy., Bracket Receiver Intake Grille Air Swing Motor Air Filter Crank Connector Grille Lock Louver Holder Discharge Foam Crank Cross Discharge Foam, LED Insulation, Long Discharge Foam, Short Insulation, Short Louver Insulation, Corner Louver, LED Parts Not in Diagram Linkage Cover...
Page 81
Indoor Unit Model: AWM10/15G2 Description Description Assy., Chasis Drain Hose Fan, Motor Assy., Control Box Cross Flow Fan Assy., Control Box Cover Fan, Bush Assy., Front Cover Assy., Coil Assy., Air Discharge Housing Piping, Clamp Assy, Mounting Plate Assy., Drain Pan Screw, S.T.
Page 82
Indoor Unit Model: AWM20/25G2 Description Description Assy., Chasis Cover, Piping Fan, Motor Assy., Control Box Cover Cross Flow Fan Assy., Front Cover Fan, Bush Service Panel Assy., Coil Assy., Air Discharge Housing Piping, Clamp Assy, Mounting Plate Assy., Drain Pan Screw, S.T.
Page 83
Indoor Unit Model: ACM20/25E Description Description Assy., Top Panel Cover, Hanger R2 (B) Assy., Coil Mounting Bracket Assy., Vane Control Module Assy., Drain Pan G18 Handset (Cooling Only) Cover, Control Box G18 Handset (Heatpump) Motor Louver Motor, Bracket Saranet Filter Blower Wheel Assy., LED Board Blower Housing...
Page 84
ACSON MALAYSIA SALES & SERVICE SDN.BHD. (129688-D) DAIKIN a member of group Lot 4, Lorong 19/1A, Seksyen 19, 46300 Petaling Jaya, Authorized Dealer : Selangor Darul Ehsan, MALAYSIA. Tel : +603 7964 8200 Sales Fax : +603 7956 9909 Service Fax : +603 7956 9907 Acson Careline : 1300 22 3344 Penang : +604-5377 176 Pahang : +609 5178 696...
Need help?
Do you have a question about the AWSS30A and is the answer not in the manual?
Questions and answers