T is an integer number ranging form 0 to 9.
The unit is degree of centigrade.
i. INVERTER Status
<U> is one byte of binary information such as <b7b6b5b4b3b2b1b0>.
Where bn is a ASCII character '0' or '1'.
INVERTER status:
j. Stop Byte
Example : Computer : Q1<cr>
Helios Power Solutions: Email - Australia: sales@heliosps.com.au - Singapore: sales@heliosps.asia - New Zealand: sales@heliosps.co.nz
: <U>-----------------------(SPEC)
Bit
7
1 : Utility Fail (Immediate)
6
1 : Battery Low
5
SPEC
4
SPEC
3
SPEC
2
SPEC
1
SPEC
0
SPEC
: <cr>
INVERTER
(208.4 140.0 208.4 034 59.9 2.05 35.0 00110000<cr>
Means : I/P voltage is 208.4V.-------------------------(SPEC)
I/P fault voltage is 140.0V.------------------(SPEC)
O/P voltage is 208.4V.
O/P current is 34%.
I/P frequency is 59.9 HZ.
Battery voltage is 2.05V.
Temperature is 35.0 degrees of centigrade.