e) Setting of switching time from keypad:
The TZM1612 performs through blank switching. Switching time can be selected by the user
for improved adaptation to the characteristics of the destination.
This important feature avoids the annoying effects that are typical of LCD devices when a
signal is switched at their input. As each LCD has its own response time, for optimal
switching, the user can modify blank duration from 0.3 to 2 seconds.
Four times can be set: 0.3 sec.; 0.5 sec.; 1 sec. and 2 sec. as per the table below. A flash of
the built-in led of buttons IN13÷IN16 indicates that the command has been saved.
The time set remains the same also for subsequent power-ons.
MODE+IN13
MODE+IN14
MODE+IN15
MODE+IN16
To display the switching time at which the TZM 1612 unit is working:
-LOCK the MODE button.
- Observe the built-in leds of buttons IN13÷IN16. The led of button IN13 indicates the
shortest time while that of button IN16 indicates the longest time.
Through blank shortest time