Technical data
A.1

General technical data

Installation location
Installation position
Degree of protection
Safety class
Cooling
Housing size: H x W x D
Weight
Operating temperature
Storage/transport
temperature
Site altitude
Vibration strain
ESD
Electromagnetic fields
BURST
Emitted interference
A-2
On system
IP 65/67
3
Convection
90 mm x 130 mm x 250 mm
1.5 kg
- 20°C to + 40°C
- 40°C to + 80°C
2000 m
4000 m
3 g
8 kV air discharge
6 kV contact discharge
10 V/m
2 kV / 5 kHz supply voltage
1 kV / 5 kHz data lines
2 kV / 5 kHz process lines
Limit value class A
• Wall-mounted (motor
nearby)
• Mounted directly on motor
(motor plugged in)
Any
Watertight to
IEC 529 (DIN 40050)
IEC 536 (VDE 0106-1)
supply with
safety extra-low voltage
No additional cooling required
Without restrictions
With restrictions, e.g. max.
ambient temperature, lower
overvoltage category
IEC 1000-4-2
severity 3
IEC 1000-4-3
severity 3
IEC 1000-4-4
severity 3
EN 55011
ECOFAST Motor Starters