Motor Starters; General Technical Data - Siemens ecofast 3RK1702-2GB18-0AA1 Manual

Table of Contents

Advertisement

Available languages

Available languages

Technical data
A.1

Motor Starters

A.1.1

General technical data

Installation location
Installation position
Degree of protection
Safety class
Cooling
Weight
-Reversing starters
-Reversing soft starters
Operating temperature
Storage/transport
temperature
Relative humidity
Site altitude
Vibration strain
Shock
ESD
Electromagnetic fields
BURST
Emitted interference
NOTICE
A-2
On system
IP65
1
Convection
1.4 kg
1.9 kg
–20 °C to +40 °C
–40 °C to +80 °C
5% to 95%
2000 m
4000 m
f = 5 to 26 Hz; d = 0.75 mm
f = 26 to 150 Hz; a = 2 g
2
a = 120 m/s
(12 g); 11 ms duration
3 shocks per +/- direction in all
of the three perpendicular axes (=18)
8 kV air discharge
6 kV contact discharge
10 V/m
2 kV / 5 kHz supply voltage
1 kV / 5 kHz data lines
2 kV / 5 kHz process lines
Limit value class A
•Wall-mounted
(motor plugged in)
•Mounted directly on motor
(motor nearby)
Any
Watertight acc. to
IEC 529 (DIN 40050)
IEC 536 (VDE 0106-1)
supply with
safety extra-low voltage
No additional cooling required
Do not allow condensation to
form!
Without restrictions
With restrictions
Reduction of I
e
by 1% per 100 m to 2,000 m
10 cycles
IEC 1000-4-2
severity 3
IEC 1000-4-3
severity 3
IEC 1000-4-4
severity 3
EN 55011
ECOFAST Motor Starters
GWA 4NEB 950 5221-12 DS 02

Advertisement

Chapters

Table of Contents
loading

Table of Contents