Bubble CORNER Installer's Instructions

Bubble CORNER Installer's Instructions

Wood and solid fuel oven stoves

Advertisement

Quick Links

W
W
O
O
D
A
N
O
O
D
A
N
I
I
M
A
R
I
N
E
M
A
R
I
N
E
© Euroship Services (UK) Ltd., Trading as:- Bubble Products 07-07-01. ©
S
F
S
F
D
O
L
I
D
U
D
O
L
I
D
U
N
S
T
A
L
L
E
R
N
S
T
A
L
L
E
R
I
1
8
-
I
1
8
-
S
S
U
E
S
S
U
E
1
O
S
O
S
E
L
V
E
N
E
L
V
E
N
I
I
N
S
T
R
U
C
N
S
T
R
U
C
0
2
-
1
5
0
2
-
1
5
T
O
V
E
S
T
O
V
E
S
T
I
O
N
S
T
I
O
N
S

Advertisement

Table of Contents
loading

Summary of Contents for Bubble CORNER

  • Page 1 © Euroship Services (UK) Ltd., Trading as:- Bubble Products 07-07-01. ©...
  • Page 2: Table Of Contents

    Hearth and Fireplace Requirements ____________________________________________ 10 Fig 2 Rectangular Appliances and Cookers Hearth Size Requirements ____________________ 11 Distances From Combustible Materials __________________________________________ 11 Fig 3 Corner Appliance Distance from combustibles ________________________________ 13 Chimney Systems. ________________________________________________________ 13 Fig 4 General Layout of Typical Flue. ___________________________________________ 14 Fig 5 General Layout of MK3 Deck Flange Assembly.
  • Page 3: Health, Safety And Warnings

    Suitably adequate equipment must be available for loading, unloading and on site appliance movement. Fireguard. A suitable fire guard conforming to BS8423:2002 should be used with all Bubble solid fuel appliances. Correct use of the appliance. The appliance should not be used with the fire door open and where applicable the ashpit door open.
  • Page 4: Rules And Regulations

    Identification. A serial number plate is fastened to the appliance and printed on the warranty document displaying information about the product. When ordering consumables and spare parts it will be necessary to quote the serial number. Consequential loss. The manufacturer will not be responsible for any consequential or incidental loss or injury however caused.
  • Page 5: Specifications

    .03"MIN TO SMALL BOILER 1-3KW 1-4KW TOP-REAR .1"MAX .03"MIN TO LARGE BOILER 2-8KW 1-3KW TOP-REAR .1"MAX OVEN STOVES .03"MIN TO CORNER POD 1-4KW TOP ONLY .08"MAX .03"MIN TO WET VERSION 1-3KW 1-2KW TOP ONLY .08"MAX .03"MIN TO 4BPOD 1-5KW TOP ONLY .08"MAX...
  • Page 6: Dimensions Stoves

    1 = airwash control, 2 = overfire air, 3 = underfire air...
  • Page 8: Wood Stove Fig 1

    1 = airwash control, 2 = overfire air...
  • Page 10: Wood Pod Fig 1

    Hearth and fireplace construction are governed by Document J of the Building Regulations for Class 1 Appliances. The stove must stand on a fireproof hearth and must not be situated too close to...
  • Page 11: Fig 2 Rectangular Appliances And Cookers Hearth Size Requirements

    Table 2 FRONT REAR SIDES ABOVE HEARTH STOVES DEPTH CORNER WET VERSION WET VERSION WET VERSION SMALL BOILER LARGE BOILER OVEN STOVES CORNER POD...
  • Page 12 WET VERSION 4BPOD WET VERSION 7BPOD SMALL BOILER LARGE BOILER MINI COOKER...
  • Page 13: Fig 3 Corner Appliance Distance From Combustibles

    Note that the wet corner stove has greatly reduced rear clearances because of the cooling effect of the wrap around water jacket. Fig 4 Rectangular Appliances and Cookers Distances from combustibles The stove must be fitted with our MK3 flue system as illustrated in figs 4 & 5.
  • Page 14: Fig 4 General Layout Of Typical Flue

    The primary flue pipe is fabricated from 4” O.D. tube with a minimum wall thickness of 3mm. It must be fitted with a flue guard to cover the possibility of anyone touching it and to comply with the distance from combustibles requirement. The flue pipe will normally run at a slight angle to allow it to terminate through the ceiling, (Max 8 deg from vertical.) in a suitable position.
  • Page 15: Fig 5 General Layout Of Mk3 Deck Flange Assembly

    These chimneys must be fitted in accordance with the manufactured instructions and current building regulations. Avoid using bends greater than 45 deg to the vertical; all flue pipe sections should be as close as possible to the vertical. Single wall flue pipe to BS 1344 part 3 is suitable for connecting from the appliance to the chimney but it is not suitable for using as a complete chimney.
  • Page 16: Connection To Flues

    1-3KW 1-2KW 27.5 2-7KW 38.5 SMALL BOILER 1-3KW 1-4KW 38.5 LARGE BOILER 2-8KW 1-3KW 11KW 60.5 OVEN STOVES CORNER MF POD 1-4KW WET VERSION 1-3KW 1-2KW 27.5 B4 MF POD 1-5KW 27.5 WET VERSION 1-3KW 1-2KW 27.5 B7POD 2-8KW 38.5...
  • Page 17: Commissioning Dry Stoves

    Make sure that the front fret is correctly fitted and that the door or doors are closed. Check the following, to make sure that they fully comply with the instructions given in these instructions. 1. Fireplace location, design and compliance with these instructions. 2.
  • Page 18: Instruct The User (Dry Stoves.)

    Grates, Ash pan, Side and Back Bricks, Baffle Plates, Door Rope Seal and Door Glass. If you have cause for dissatisfaction with your Bubble appliance you should first contact the Bubble dealer or whoever you purchased the appliance from.
  • Page 19: Glossary Of Terms

    We will either send replacement parts or nominate a regional engineer to inspect the appliance and carry out any remedial work that may be required. If the fault or problem is not due to faulty manufacture but some other cause such as:- Misuse, failure to install correctly, failure to service at regular intervals, a charge will be made to cover the cost of the visit and any new parts required.
  • Page 20 This publication is intended only to assist the reader in the use of this product and therefore Bubble Products shall not be liable for any loss or damage whatsoever arising from the use of any information, error or omission found in this publication...