Suitably adequate equipment must be available for loading, unloading and on site appliance movement. Fireguard. A suitable fire guard conforming to BS8423:2002 should be used with all Bubble solid fuel appliances. Correct use of the appliance. The appliance should not be used with the fire door open and where applicable the ashpit door open.
Identification. A serial number plate is fastened to the appliance and printed on the warranty document displaying information about the product. When ordering consumables and spare parts it will be necessary to quote the serial number. Consequential loss. The manufacturer will not be responsible for any consequential or incidental loss or injury however caused.
.03"MIN TO SMALL BOILER 1-3KW 1-4KW TOP-REAR .1"MAX .03"MIN TO LARGE BOILER 2-8KW 1-3KW TOP-REAR .1"MAX OVEN STOVES .03"MIN TO CORNER POD 1-4KW TOP ONLY .08"MAX .03"MIN TO WET VERSION 1-3KW 1-2KW TOP ONLY .08"MAX .03"MIN TO 4BPOD 1-5KW TOP ONLY .08"MAX...
Hearth and fireplace construction are governed by Document J of the Building Regulations for Class 1 Appliances. The stove must stand on a fireproof hearth and must not be situated too close to...
Note that the wet corner stove has greatly reduced rear clearances because of the cooling effect of the wrap around water jacket. Fig 4 Rectangular Appliances and Cookers Distances from combustibles The stove must be fitted with our MK3 flue system as illustrated in figs 4 & 5.
The primary flue pipe is fabricated from 4” O.D. tube with a minimum wall thickness of 3mm. It must be fitted with a flue guard to cover the possibility of anyone touching it and to comply with the distance from combustibles requirement. The flue pipe will normally run at a slight angle to allow it to terminate through the ceiling, (Max 8 deg from vertical.) in a suitable position.
These chimneys must be fitted in accordance with the manufactured instructions and current building regulations. Avoid using bends greater than 45 deg to the vertical; all flue pipe sections should be as close as possible to the vertical. Single wall flue pipe to BS 1344 part 3 is suitable for connecting from the appliance to the chimney but it is not suitable for using as a complete chimney.
Make sure that the front fret is correctly fitted and that the door or doors are closed. Check the following, to make sure that they fully comply with the instructions given in these instructions. 1. Fireplace location, design and compliance with these instructions. 2.
Grates, Ash pan, Side and Back Bricks, Baffle Plates, Door Rope Seal and Door Glass. If you have cause for dissatisfaction with your Bubble appliance you should first contact the Bubble dealer or whoever you purchased the appliance from.
We will either send replacement parts or nominate a regional engineer to inspect the appliance and carry out any remedial work that may be required. If the fault or problem is not due to faulty manufacture but some other cause such as:- Misuse, failure to install correctly, failure to service at regular intervals, a charge will be made to cover the cost of the visit and any new parts required.