Hussmann Excel Installation & Service Manual page 18

Self-contained medium temperature bakery merchandisers
Table of Contents

Advertisement

I
1-12
NSTALLATION
NOTE:
Each light fixture has a
light switch located at the left-hand
end behind the fluorescent lamps.
Each ballast is attached to a cover
plate which is fastened to the
underside of the light fixture.
JOINING LIGHT BARS
7
Mount each light bar
assembly to its case.
8
Before placing cases in lineup,
remove the light fixture's End
Caps from each of the joining
cases. This will expose the
Light Channels.
To remove the end caps use a
9
screw driver to take out the
four Snap Rivets. Discard the
end caps.
Place cases in lineup.
10
Fasten the light channels
together by joining the "L"
brackets (see Detail) using
Screws –10,
Flat Washers – 4, and
Hex Nuts –11.
"L"
Bracket
4
10
Snap
Rivets
Detail
Joining Light Bars
Ballast
Snap Rivet
Ballast
Access Plate
Light Channel
End Cap
Light Fixture Assembly
11
4
End Cap
P/N 0518279_A
Exterior Channel
Light
Light Channel
Support Bracket
Light Channel
Harness
U.S. & Canada 1-800-922-