8)
Check that "Input Drive Data" screen is displayed.
9)
Input serial No. and media remarks.
For example:
Hard disk ..................................................................... HDD
Memory Stick PRO ........................................................ MS
CompactFlash ................................................................. CF
Microdrive ..................................................................... MD
10) Click "OK" button.
11) "Storage device test" is performed automatically.
12) When the "Count" of the ERROR RATE window reaches the
following value, click "Test Abort" button to abort the test.
Storage media
Memory
Stick PRO Flash
Count
200
13) Check that error rate satisfies the specified value.
Note: 0.000000E + 000 = 0.000000 × 10
5.000000E – 002 = 5.000000 × 10
HDPS-M10
Fig. 3-1-16.
Compact
Microdrive Hard disk
200
200
1000
= 0.000000 × 1 = 0 = 0%
0
= 5.000000 × 0.01 = 0.05 = 5%
–2
Fig. 3-1-17.
3-2-6.

Burn In (Read) Check

Mode
Power Supply
Test Program
MemoryStick
CompactFlash
Microdrive
Specified Value
Checking method:
1) Turn on the power of HDPS-M10.
2) Connect HDPS-M10 and PC using the USB cable.
3) Double click "strdevtst7.exe" of the "FC2_BI(r)" folder, and
start "Storage device test" on the PC.
4) Check that "Storage device test" screen is displayed.
5) Set up "Storage device test" as follows.
Drive name (Note)
Read
Write
Random
Verify
Time out setting
Automatic
If error occurred,
display warning
Note: The drive letter (e.g., "G:") of the hard disk drive differs depending
on the PC.
6) Click "Test Start" button.
3-9
USB
AC power adaptor
strdevtst7.exe
Not necessary
Not necessary
Not necessary
Hard disk drive: Errors count = 0
Fig. 3-1-18.
G
Check
No check
No check
No check
4000msec
No check
Check

Advertisement