Dorma ED400 Installer Manual
Dorma ED400 Installer Manual

Dorma ED400 Installer Manual

Concealed “in floor” automatic swing door controller

Advertisement

DORMA
DORMA AUTOMATICS, Inc.
ED400 In Floor
Controller Manual
ED400 Concealed "In Floor"
AUTOMATIC SWING DOOR
Controller Installer's Manual
Distributed by:
924 Sherwood Drive
Lake Bluff, IL 60044
E-mail: automatics@dorma-usa.com
Toll-Free: 877-367-6211
Fax: 877-423-7999
Subject to change without notice
1
DL3128-010
10/1/2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ED400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dorma ED400

  • Page 1 DORMA ED400 In Floor Controller Manual ED400 Concealed “In Floor” AUTOMATIC SWING DOOR Controller Installer’s Manual Distributed by: DORMA AUTOMATICS, Inc. 924 Sherwood Drive Toll-Free: 877-367-6211 DL3128-010 Lake Bluff, IL 60044 Fax: 877-423-7999 10/1/2007 E-mail: automatics@dorma-usa.com Subject to change without notice...
  • Page 2: Table Of Contents

    ED400 In Floor DORMA Controller Manual ED-400 SWING DOOR CONCEALED “IN FLOOR” OPENERCONTROLLER INSTALLER'S MANUAL Rev0.56 INTRODUCTION ........................3 INSTALLATION ........................3 Operator installation ......................3 Controller installation ......................3 SET-UP ..........................6 OPERATION ......................... 9 Opener Type ........................... 9 Selected Features ........................
  • Page 3: Introduction

    Controller Manual INTRODUCTION The ED400 is an electro mechanical, automatic opener, for single direction swing doors (left or right hand). The opener opens the door using electrical power, and closes it using a return spring. The manager may turn it Off, turn it On (automatic) or place it in Hold Open (to keep the door open indefinitely).
  • Page 4 ED400 In Floor DORMA Controller Manual Sensors • Get power for any sensors that require it from any of the screws in the "+24" terminal block, and any of the screws in the "GND" terminal block. These are the 2, 8-screw, blue terminal blocks on the right end of the front panel.
  • Page 5 Door or arm installation Refer to either the Surface Applied or Ovoerhead Concealed Mount, ED400 Installation Instructions on mounting the door or the arm. If the installation procedure requires that the operator’s pinion be in moved in the open position, you may use the controller to do so, as follows.
  • Page 6: Set-Up

    ED400 In Floor DORMA Controller Manual SET-UP User Interface The controller user interface is quite intuitive. SELECT It includes a display and two rotary switches DIAL (knobs). DISPLAY Use the top knob ("SELECTOR") to select the function. TYPE LEARN MOUNT...
  • Page 7 ED400 In Floor DORMA Controller Manual Move the Program Switch from the "Off" position the "Auto" position. The door stays closed for 10 seconds to let you get out of its way. Then the door will start opening slowly. Temporarily, place a hard stop (such as your foot) at the desired Back-Stop.
  • Page 8 ED400 In Floor DORMA Controller Manual This table lists the basic settings. Position of Function of "Selector" knob "Dial" knob Display Units Type Opener Type “L.E.”: Low Energy, “P.A.”: Power Assist; “Ful”: full power Mount Select door mount Use “OCN” Setting...
  • Page 9: Operation

    ED400 In Floor DORMA Controller Manual Monitoring For troubleshooting purposes, the controller displays its Program State when the Selector knob is in the Run position, and its Learn State when the Selector knob is in the Learn position. The state and value of many more variables can be seen through the Monitor menus, such as: •...
  • Page 10: Selected Features

    ED400 In Floor DORMA Controller Manual Selected Features Push-and-go If this feature is on, and if the Program Switch is in Auto, the user may also trigger an opening by starting to open the door by hand. Also, if the door is closing, and the user reopens it manually, the opener is retriggered. Note that if the user simply stops the closing door, the opener will consider that an obstacle, not a Push-and-go trigger.
  • Page 11: Presence

    ED400 In Floor DORMA Controller Manual Presence The opener may detect people or objects in the proximity of the door. In that case, the opener modifies its behavior to avoid hitting anyone or anything in its path. Before a Power Opening - The opener waits for the swing area to be clear.
  • Page 12 ED400 In Floor DORMA Controller Manual Run menu Usually, the "Run" menu displays a code for the State of the opener. See the Program State section, later. However, if there is an exception, the Run menu flashes a code for the exception; it does so from the moment when it occurs, until the next opening cycle starts.
  • Page 13: Misc. Adjustments Menus

    ED400 In Floor DORMA Controller Manual Back-Stop menu This menu displays and lets you set the Electrical Back-Stop angle (in °). During a Power Opening, this is where the door stops. This should be less than the mechanical Back-Stop (which may be set by the operator, or by where the door would encounter a physical stop).
  • Page 14 DORMA ED400 In Floor Controller Manual Items that use a numeric value show instead of '0'. Features show Power Hold submenu - If the door has a hard-stop at Latch-Stop, the opener may use additional force to press the door against the stop.
  • Page 15: Monitor Select And Monitor Values Menus

    ED400 In Floor DORMA Controller Manual Monitor Select and Monitor Value menus These 2 menus work together to display the valueof many minor items. The first one is used to select an item, and the second one to display its value.
  • Page 16: Troubleshooting

    ED400 In Floor DORMA Controller Manual TROUBLESHOOTING Electrical Fuse replacement The controller has 2 fuses, one on the AC line input, one on the motor output. If the input fuse blows, the controller is completely off (no display). If the output fuse blows, the controller comeson, but there's no motor drive.
  • Page 17 ED400 In Floor DORMA Controller Manual Output LEDs Each output line has an LED a to indicate its status. This is what it means when the LEDs are lit: Reason for being lit A DK12 is connected to the controller, and the door is not closed, telling Data ███...
  • Page 18: Particular Siuation Troubleshooting

    ED400 In Floor DORMA Controller Manual Bad value Due to unusual circumstances, an operating parameter may take a value outside its allowed limits. The controller constantlychecks the operating parameter; if it finds a problem with their value, it logs the problem and restarts the program from scratch. After the entry, the next 2 items in the log are the address of the variable, and the bad value.
  • Page 19 ED400 In Floor DORMA Controller Manual Opener won't learn To start a learn cycle, the following must happen: • Power must be on • There must not be an alarm • The Selector knob must be in the Learn position •...
  • Page 20 ED400 In Floor DORMA Controller Manual Opener keeps door open against the operator's hard-stop This may happen for these reasons: • There is a temporary soft failure – remove power to the controller and turn it back on • If the problem persists, the controller may have forgotten some parameters – do a learn cycle •...
  • Page 21 ED400 In Floor DORMA Controller Manual Opening door bumps against the hard-stop The controller learned the Electrical Back-Stop to be the same as the mechanical hard-stop. That is probably because either • you didn't stop the door at the Electrical Back-Stop during the slow learning cycle, during initial set-up, or •...
  • Page 22: Specifications

    ED400 In Floor DORMA Controller Manual SPECIFICATIONS Main features • Overhead Concealed Mount or surface mount (push or pull) • Center pivot or offset hinges • Complete: doesn't require a power-boost module, nor a brake box • Hand is field reversible Control inputs •...
  • Page 23: Appendix

    ED400 In Floor DORMA Controller Manual APPENDIX WIRING Encoder / Cam Switch wiring Encoder only the 4 wires from the encoder should already be connected properly to the 5-position connector. If you need to wire it, here is how. GROUND...
  • Page 24: Pairs Of Doors

    ED400 In Floor DORMA Controller Manual Pair of Doors Two openers may be used to open two side-by-side doors. The doors may be synchronized or not. This operator is not compatible with over-rebated doors. Synchronized doors The doors behave as if they are mechanically interconnected. In case of a presence at one door, both doors react identically.
  • Page 25 ED400 In Floor DORMA Controller Manual Set-up: • Program the two controllers identically. However, in particular situations you may wantto program them slightly differently, so that one door opens and/or closes first. • Let the openers do a learn cycle (it’s easier if you do them separately). Tip to stagger the opening of the doors during the learn cycle: place both controllers in “Learn”;...
  • Page 26: Operation

    ED400 In Floor DORMA Controller Manual OPERATION Restore factory defaults To reset the unit to the factory defaults, do the following: Turn the "Selector" knob to the "Misc Sel" position. Turn the "Dial" knob until "rSt" is shown in the display.

Table of Contents