Connection Diagram; Connection Diagram: Parallel Connection; Commissioning; Error Detection And Indication - TCS FVM1000 Product Information

Central image buffer
Table of Contents

Advertisement

Connection diagram

First install the system completely, then connect it to the main voltage!
• V1 and V2 must not be connected with the P-, a- or b-wire.
!
• When connecting the video wires V1 (+) and V2 (-) the polarity must be observed. If
the image is distorted after the commissioning, switch off the device and exchange
the wires for the video signal.
If the FVM1000 is installed as the only or as the last device at the end of a TCS:BUS
video strand, the terminating resistor J1 must stay plugged (position ON, see type
!
label)!
Otherwise the terminating resistor J1 has to be removed.
• Ensure that the SD card is plugged into the SD slot according to the marking on the
type label. The SD card is needed for the storage of all configuration data and images. It
must always stay in the device.
For safe operation, only the enclosed SD card is to be used with the device.
!
As spare part, the SD card can be ordered directly from TCS (see Spare parts, acces-
sory).
• Switch on the mains voltage. The device is ready for operation.

Error detection and indication

Errors are signaled optically by permanent flashing of the red LED and acoustical by a
unique tone sequence. The optical error indication stays active until the error is eliminated.
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
FAX: +49 (0) 41 94/ 9 88 129 • Mail: hotline@tcsag.de
8

Connection diagram: parallel connection

max. 5 image buffer

Commissioning

Subject to technical changes.
PI_FVM1000-0400_uk.doc
05/2013
Revision: 1