Page 1
Product information Power supply and control unit VBVS05-SG for small and medium-sized systems TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes. TCS Hotline Germany • Mail: hotline@tcsag.de PI_VBVS05-uk...
When working in systems with 230 V mains voltage, the safety requirements according to DIN VDE 0100 must be observed. When installing TCS:BUS systems, the general safety regulations for telecommunication systems according to VDE 0800 must be observed. Inter alia: ...
11/2012 Usage The VBVS05-SG is used for the central supply and control of small and medium-sized vid- eo or audio systems with one strand. The loop resistance must not exceed max. 5 Ohm (when in 5-wire operation). The device can be used exclusively to supply the TCS:BUS. Any other use is considered improper and is prohibited.
Preferably, the video terminals V1 and V2 of the indoor and front-door station have to be con- nected directly. The terminals 32, 33 of the VBVS05 can be used as auxiliary terminals. Connection diagram TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes. TCS Hotline Germany Mail: hotline@tcsag.de PI_VBVS05-uk - uk...
Page 6
Legend to setting, programming, operation Press button until … LED blinks slowly Shortly press button LED is ON Release button further TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes. TCS Hotline Germany Mail: hotline@tcsag.de PI_VBVS05-uk - uk...
VBVS05 repair (replace) Speaking at the indoor station By interchanging or short-circuit is very quiet. of the a-P-wires, a resistor at the VBVS05 was damaged. TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes. TCS Hotline Germany Mail: hotline@tcsag.de PI_VBVS05-uk - uk...
Need help?
Do you have a question about the VBVS05-SG and is the answer not in the manual?
Questions and answers