1200 Baud Rate Switch Settings
1. Remove the CAS's cover by following Steps 1 through 5 in the section
of this document titled "Setting System Options."
2. To change the baud rate to 300, slide switch number 5 up and switch
number 7 down (switch number 6 remains down) on Switch Box 3.
3. To change the baud rate to 600, slide switch number 6 up and switch
number 7 down (switch number 5 remains down) on Switch Box 3.
4. Replace the CAS's cover following the instructions in the section below.
REPLACING THE CAS's COVER
1. Position the base of the CAS so its front is facing you.
2. Hold the cover so that it is right side up and the ventilation slots are at
the back of the unit (Figure 13).
Cover
14
Switch box 3
1 2 3 4 5 6 7
Figure 12
Figure 13
Replacing the Cover
Ventilation slots